Power Quality Analyzer with Current True RMS Max Error ±(2 % +3dgt) 1.0A~1000A


Introduction of Power quality analyzer:



Introduction of Clamp Current Sensor:


  • Clamp current sensor is a high-precision AC current convector. It adopts the latest CT technology and is designed with a large-diameter circular structure. It can be used for quick and easy free access. 
  • The compact size is easier to carry and use. Applicable to AC current, high harmonic current, phase, electric energy, power, power factor and other tests.
  • It can be used with a variety of measuring instruments, such as: Field calibrator for watt-hour meter, harmonic analyzer, recorder, multi-function energy meter, oscilloscope, digital multimeter, cable identification, cable fault detector, double clamp grounding resistance Testers, double-clamp phase volt-ampere meters, etc., can measure and compare various electrical parameters under constant power. 
  • Widely used in substations, power plants, industrial and mining enterprises and testing stations, electrical maintenance departments for current detection and field electrical work.



Specifications:

Power supply

Rechargeable lithium-ion battery packs 9.6V, backup charger.

Battery indicator

Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.

Power consumption

Current consumption of normal test 490 mA, continuous working for 10 hours.

Display mode

LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.

Size of clamp

Circle current clamp: 50mm×50mm;

Instrument dimensions

L×W×H: 277.2mm ×227.5mm ×153mm.

Number of channels

4U/4I.

Phase-to phase voltage

1.0V~2000V.

Phase-to-neutral voltage

1.0V~1000V.

Current

Current clamp: 1.0A~1000A;

Frequency

40Hz~70Hz.

Parameters of electricity

W, VA, Var, PF, DPF, cosφ, tanφ.

Energy parameters

Wh, Varh, Vah.

Harmonic

Order 0~50.

Total harmonic distortion

Order 0~50, each phase.

Expert mode

Yes.

Number of Transient records

150 sets.

Voltage flicker

Yes.

Starting current mode

Yes, 100 seconds.

3 phases unbalance

Yes.

Record

300 days(simultaneous recording 20 parameters, record one point every 5 seconds).

Min/Max recorded value

Measurement of maximum and minimum values over a period of time.

Alarm

40 different types of parameter selections, 12,800 sets alarm logs.

Peak

Yes.

Phasor diagram display

Automatically.

Capacity of snapshots

60.

Menu language

English/Chinese.

Communication

USB.

Automatic switching off

When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.

In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.

Backlight function

Yes, suitable for use at night and dark place.

Weight

Host: 1.6kg (with battery).

circle current clamp: 252g×4;

Test wires and power adapter: 800g;

Total weight: about 10.8kg (with packaging).

Length of voltage test wire

3m.

Length of current sensor wire

2m.

Working temperature and humidity

-10°C~40°C; below 80%Rh.

Storage temperature and humidity

-10°C~60°C; below 70%Rh.

Input impedance

Input impedance of test voltage: 1MΩ.

Withstand voltage

Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.

Insulation

Between instrument wiring and shell 10MΩ.

Structure

Double insulation, with insulation vibration-proof sheath.

Safely rules

IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.