Victron Cyrix-Li-charge 12/24V-120A intelligent charge relay

Victron Cyrix-Li-charge 12/24V-120A intelligent charge relay

The Cyrix Battery Combiner is a microprocessor controlled heavy duty relay that automatically connects batteries in parallel when one of them has reached a pre-set voltage (indicating that the battery is being charged), and disconnects when the voltage decreases below float level (indicating that one or more batteries are being discharged). Cyrix Battery Combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased. The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay: - if the charge disconnect output of the VE.Bus BMS is high, and - if it senses 13,0 V (resp. 26,0 V or 52,0 V) or more on its battery charger connection terminal, and - if it senses 2 V or more on its battery terminal (the Cyrix will remain open if not connect to the battery). The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over temperature. In general, a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3 seconds When the Cyrix-Li-Charge is engaged (charger connected to battery) it will disengage after 1 hour to check if the charger is still enabled. If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13,0 V or more, the Cyrix will reengage, with a 3 seconds delay. Note: In case of zero discharge current, or a small discharge current, the Cyrix will not disengage shortly after the charger has been switched off and/or disconnected, because battery voltage will remain higher than 13,5 V.
 

Service

Do you want to add freight insurance? Please contact us to organise a suitable insurance option.

If you do not opt for freight insurance your goods will be freighted uninsured which means you assume all responsibility for loss or damage of goods during shipping. No liability will be accepted by Preston Off Grid if you do not select the freight insurance option.

If your delivery arrives in a damaged state, please refuse to sign for or accept delivery of any packages. Please document any damage with photographs and contact us immediately to report the item as damaged upon delivery. We accept no liability for damages or losses on uninsured freight.