Dresser Roots Gas Flow Meter Series B3, 5M175

PN: 5M175

The Dresser Roots Gas Flow Meter Series B3, 5M175 is a rotary gas meter that is designed to provide accurate gas measurement over widely fluctuating flow, pressure and temperature conditions. The meter has a capacity of 5000 acfh, a maximum allowable operating pressure of 175 psig, and an operating temperature range of -40°F to +140°F. 

                                           UNITS Imperial                                      UNITS Metric

Temperature Range deg:        F -40 to +140                                        deg. C -40 to +60

Base Rating (Q Max.):            acfh 5000 m3 /h                                    141,5

Max. Operating Pressure:       psig 175 kPa                                          1200

Leak Test (125% MAOP):       psig 219                                                 kPa 1510

Static Test (2 x MAOP):          psig 350                                                kPa 2400

Rangeability +/- 1%:             ratio 120:1                                            ratio 120:1

Rangeability +/- 2%:             ratio 215:1                                            ratio 215:1

Start Rate:                            cfh 1.2                                                  m3 /h 0,0340

Stop Rate:                            cfh 0.8                                                   m3 /h 0,0227

Flow Rate @ 0.5” w.c., Gas:   cfh 3975                                                 m3 /h 112,6

Avg. Differential 100% Flow:  in. w.c. 1.05                                           mbar 2,6

Max. Pressurization Rate:       psig/sec 5                                              kPa/sec 35

Max. Operating Speed:          rpm 2250                                               rpm 2250

Gear Ratio:                           ratio 270:1                                             ratio 953,125:1

Displaced Volume/Revolution:cf 0.037037 m3                                       0,0001049

Drive Rate, CD:                    cf/rev 10                                                 m3 /rev 1

Drive Rate, TD:                    cf/rev 100                                                m3 /rev 10

Temp. Compensating Range (TC, TD):

                                           deg. F -20 to +120                                   deg. C -20 to +50

Min. Odometer Reading:        cf 0.2                                                      m3 0.02

Odometer Turnover:              yrs. 2.28                                                 yrs. 8,06

Nominal Pipe Size:                in. 3                                                        mm 80

Flange-to-Flange:                 in. 6-3/4                                                  mm 172

Flange Connection:              ANSI 150#FF                                            ANSI 150#FF

Bolts per Flange:                 qty. 4                                                       qty. 4

Bolt Size:                            in. 5/8 - 11                                              in. 5/8 - 11

Flange Bolt Hole Depth:       in. 15/16                                                  mm 23,8

Bolt Torque: Lubricated/Non-Lub:

                                          ft.-lb. 55/60                                             N-m 74/81

Restricting Orifice (120%):   in. 23/32                                                  mm 18,256

Oil Capacity – Side Inlet:     oz. 1.25                                                    ml 37

Oil Capacity – Top Inlet:      oz. 7.65                                                    ml 226