main feature
1.10Hz ~1MHz wide test frequency
2. 6 and a half digits of measurement resolution
3. Internal ±2V DC bias voltage
4. 0.05% basic measurement accuracy
5. Automatic, manual, external trigger and bus trigger measurement
6. Dual measurement display
7. Measured in the form of absolute value, or measured in the form of deviation based on the reference value
8. Precise four-wire fixture
9. Component classification
10. Up to ±60V DC external bias voltage
11. Internal memory
12. 7-inch LCD color screen display
13. Intuitive user interface, comprehensive test functions
14.Provide the RS232,HANDLER,GPIB,LAN,USB interface.
specification | 4092A | 4092B | 4092C | 4092D | 4092E |
frequency (1mHz step) | 10Hz-100kHz | 10Hz-200kHz | 10Hz-300kHz | 10Hz-500kHz | 10Hz-1MHz |
Measurable parameters | Cp-D/Q/G/Rp, Cs-D/Q/Rs, | ||||
measure time (Fast/medium speed) | 200ms/500ms @ 10Hz | ||||
Custom time range | 100ms/2000ms @ 10Hz | ||||
Test signal level (1mVrms step) | 10mVrms-2Vrms | ||||
Constant voltage level | 10mVrms-1Vrms | ||||
Constant current level | 100μArms-10mArms | ||||
DC bias capability | Internal -2V to +2V voltage bias, external bias input (within ±60V) | ||||
Signal source internal resistance | 30 ohm, 100 ohm optional | ||||
Basic accuracy | 0.05% | ||||
display resolution | 6 and a half | ||||
Comparators | 9 combination grid files, 1 group of unqualified files, and a group of auxiliary files | ||||
calibration | Self-calibration, open/short frequency sweep, 100 groups of designated frequency points | ||||
List scan | 100-point list sweep test | ||||
Storage device | Internal/USB storage | ||||
remote control | GPIB、LAN、RS232、USB、Handler | ||||