This is digital multifunctional meter can be used to measure voltage, discharge current, discharge power , discharge impedance,
internal resistance, capacity, energy, soc, running time
Voltage
- Measuring range: 0-200V (8V,please use the independent power supply mode)
- Display format: <10V display as: 9.9V
<100V display as: 99.9V
≥100V display as: 199V
- The starting test voltage: 0.05V
- Minimum resolution: 0.01V
- Measurement accuracy: 1%
Current:
- Measuring range: 0-200A
- Display format: <1A display as: 999mA
<10A display as: 9.99A
<100A display as: 99.9A
≥100A display as: 199A
- Minimum resolution: 1mA
- The starting test current: 20mA
- Measurement accuracy: 1%
Power:
- Measuring range: 0-2000W / 0-6000W
- Display format: <10W display as: 9.99W
<100W display as: 99.9W
<1000W display as: 999W
<10000W display as: 9.99kW
≥10000W display as: 19.9kw
- Minimum resolution: 0.01W
- The starting test power: 0.2W
- Measurement accuracy: 1%
Impedance:
- Impedance=Voltage/Current
- Measuring range: 0-1000Ω
- Display format: <100Ω display as: 99.9Ω
≥100Ω diplay as: 999Ω
- When over the test range or the current is zero, it display "---"
- Minimum resolution: 0.1Ω
- Measurement accuracy: 1%
Internal Resistance:
- Internal resistance=(Full voltage - Bring load voltage)/Bring load current, when the bring load voltage is larger than the
maximum voltage, the internal resistance is zero
- Measuring range: 0-999mΩ
- Diplay format: 999mΩ, when over the test range of the current is zero, it display "---"
- Minimum resolution: 1mΩ
- Measuremnt accuracy: 1%
Capacity:
- Measuring range: 0-1000AH
- Display format: <1AH display as: 999mAH
<10AH display as: 9.99AH
<100AH display as: 99.9AH
<1000AH display as: 999AH
- Minimum resolution: 1mAH
- Measuremnt accuracy: 1%
SOC:
- SOC is display via the battery symbol, totally 10 grids, every grid present 10% energy
- SOC is calculated via the current battery value, before test you should preset the full voltage and the cut-off voltage depend
on the battery type; every grid voltage= (the highest voltage - the lowest voltage)/10
Energy:
- Measuring range: 0-9999kWh
- Display format: <1kWh display as: 999Wh
<10kWh display as: 9.99kWh
<100kWh display as: 99.99kWh
<1000kWh display as: 999.99kWh
≥1000kWh display as: 9999kWh
- Over the test range will become zero
- Minimum resolution: 1Wh
- Measuremnt accuracy: 1%
Running time:
- Measuring range: 0-999 hour(without load the time will not accumulate)
- Display format: 0:00:00~999:59:59
Package included:
1 * DC 0-200V multifunction meter
1 * 200A Shunt
1 * Cables
1 * Manual