The FRM01 is a multifunction relay control module that features 18 programmable functions. With 2 separate timers that can be set from 0.1 seconds all the way through to 270 hours, the ability for infinite loop or set amount of loop times and the ability to trigger an event with a high signal.
Coil voltage: 12V DC
Contact rating: 10A
Switching voltage AC: 250VAC Max
Switching voltage DC: 30VDC Max
18 User programmable functions
3 Wire interface on input and output
Dimensions: Approx. 6.6 x 4 cm
Functions:
Function 1: When power is applied, CH1 will be LOW, T1 (Timer 1) will count down, once T1 reaches 0 CH1 will switch to HIGH.
Function 2: When power is applied, CH1 will be HIGH, T1 (Timer 1) will count down, once T1 reaches 0, CH1 will switch to LOW.
Function 3: When power is applied CH1 will be LOW, T1 (Timer 1) will count down, once T1 reaches 0, CH1 will switch to HIGH. T2 (Timer 2) will then start to count down, once T2 reaches 0, CH1 will switch to LOW.
Function 4: When power is applied CH1 will be HIGH, T1 (Timer 1) will count down, once T1 reaches 0, CH1 will switch to HIGH. T2 (Timer 2) will then start to count down, once T2 reaches 0, CH1 will switch to HIGH.
Function 5: When power is applied CH1 will be LOW, T1 (Timer 1) will count down, once T1 reaches 0, CH1 will switch to LOW. T2 (Timer 2) will then start to count down, once T2 reaches 0 CH1 will switch to LOW. This will continue to loop.
Function 6: When power is applied CH1 will be HIGH, T1 (Timer 1) will count down, once T1 reaches 0, CH1 will switch to LOW. T2 (Timer 2) will then start to count down, once T2 reaches 0 CH1 will switch to HIGH. This will continue to loop.
Function 7: When power is applied CHI1 will be LOW, T1 (Timer 1) will count down, once T1 reaches 0, CH1 will switch to HIGH, T2 (Timer 2) will then start to count down, once T2 reaches 0 CH1 will switch to LOW. This will loop a set amount of times which is set by the NX function.
Function 8: When power is applied CH1 will be HIGH, T1 (Timer 1) will count down, once T1 reaches 0, CH1 will switch to LOW, T2 (Timer 2) will then start to count down, once T2 reaches 0 CH1 will switch to HIGH. This will loop a set amount of times which is set by the NX function.
Function 9: While power is applied, a high-level signal can be sent which triggers CH1 to HIGH, another high-level signal can be sent to set CH1 to LOW.
Function 10: While power is applied, a high-level signal can be applied to set CH1 to HIGH. T1 (Timer 1) will count down, once T1 reaches zero, CH1 will be set to LOW.
Function 11: When power is applied, CH1 is LOW, a high-level signal can be sent which triggers T1 (Timer 1) to count down, once T1 reaches 0 CH1 will be HIGH, applying a high-level signal during CH1 being HIGH, will set CH1 to LOW and trigger T1 to countdown again.
Function 12: When power is applied CH1 is LOW, a high-level signal sets CH1 to HIGH and starts T1 (Timer 1) countdown, once T1 reaches 0, CH1 will go to LOW.
Function 13: When power is applied CH1 is LOW, T1 (Time 1) starts to countdown, when T1 reaches 0 CH1 goes to HIGH and T2 (Timer 2) starts to countdown. When T2 reaches 0, CH1 is LOW.
Function 14: When power is applied CH1 is LOW, a high-level signal switches CH1 to HIGH and T1 (Timer 1) starts to countdown, once T1 reaches 0, CH1 goes to LOW and T2 (Timer 2) starts to countdown, Once T2 reaches 0 CH1 goes to HIGH.
Function 15: When power is applied CH1 is low, a high-level signal start T1 (Timer 1), when T1 reaches 0 CH1 goes to HIGH and T2 (Timer 2) starts to countdown, once T2 reaches 0 CH1 goes to LOW and loops the process.
Function 16: When power is applied CH1 is LOW, a high-level signal starts T1 (Timer 1) and set CH1 to HIGH, when T1 reaches 0 CH1 goes to LOW and T2 (Timer 2) starts. When T2 reaches 0 CH1 is set to HIGH and loops the process.
Function 17: When power is applied CH1 is low, a high-level signal start T1 (Timer 1), when T1 reaches 0 CH1 goes to HIGH and T2 (Timer 2) starts to countdown, once T2 reaches 0 CH1 goes to LOW and loops X amount of times as set by NX parameter.
Function 18: When power is applied CH1 is LOW, a high-level signal starts T1 (Timer 1) and set CH1 to HIGH, when T1 reaches 0 CH1 goes to LOW and T2 (Timer 2) starts. When T2 reaches 0 CH1 is set to HIGH and loops X amount of times as set by NX parameter.
We test/examine all the products before sent out. If you experience any problems, please contact us directly and we will do our best to resolve any issues.
If you are not totally happy with our product, you can return it to us within 30 days from the date of purchase.Please note that the returned item must be in its original packaging with all accessories, and in the same condition as when you received it.We will gladly refund you the total amount less the Shipping & Handling costs.
Shipping
We ship all orders placed before 4 pmon the same or the next business day.
All items will be shipped via Australia Post unless specified otherwise.
Free Shipping via Australian Post generally takes 2-6 business days.
Express Delivery within Australia generally takes 1-3 business days.
Local pick-up is available (only bulk orders); please contact us to arrange a time for pick-up.
We can be contacted at any time through eBay messages if you have any questions, comments or product requests. We will respond within 24 hours and do our best to help you out.
We encourage our customers to contact us with any questions or concerns. We would like to be sure you are completely satisfied with your purchase.