new omron digital temperature controller E5CC-RX3A5M-000 multi range 100-240 VAC

universal !!! for all t.c like the J K S and more and all RTD like the PT-100 PT-1000 and more

FOR 110VAC like in USA

AND FOR ALLSO 230VAC LIKE IN EUROPE

FOR MORE Q I WILL ANSWER VERY FAST




E5CC, E5CC-U

Digital Temperature Controller (48 x 48 mm)


48 x 48 mm. Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications.

about this Product Family


The new standard in temperature control...

Omron has been an active innovator in temperature control since introducing its first temperature controller in 1967. Now temperature control has taken a giant leap forward with Omron's next generation of controllers - the E5[]C, which set new global standards in the crucial areas of precision, user friendliness and control performance. The E5[]C series will save you time and effort in set-up and operation, while enabling faster and more accurate monitoring/control of your process. The high-visibility display of the new series is also extremely easy to read and virtually eliminates any possibility for human error.

Key features

  • High-contrast, white LCD display visible from large distances and from any angle
  • Easy to set up, and operate intuitively via CX-Thermo without power supply
  • 50 ms sampling period for fast and precise regulation
  • Functions for diagnosis for secure operations *
  • Useful timer and logic operation functions eliminating the need of a PLC
* Alarm for loop break or PV change rate, heater burnout or sensor burnout detection

...is higher in every respect

Clearer LCD display

The large, high-contrast, white LCD display contributes to the exceptional clarity and therefore readability of the E5[]C series. The display can be read unambiguously from greater distances and from much wider viewing angles than normal.

Easy set-up and operation

Coupled with the autotuning algorithms, which greatly reduce set-up and commissioning time, Omron’s CX-Thermo support software has been specially developed for use with the E5[]C series. This enables faster parameter set-up, easier device adjustment and simpler maintenance.

Unique performance

Although intrinsic high sampling speed and high precision are built into the E5[]C series, Omron's 2-PID control is a key factor behind the advantage it offers over standard controllers. Using a powerful algorithm, it makes all the difference to control stability and thus the quality of your products.

High-contrast display

Easy-to-read White Characters with Large Display Size *1

Big white characters on a black background achieve superior visibility.
You can quickly and reliably check the PV from wide viewing angles, with natural light or in the subdued lighting conditions.

Character Height *1 (White PV)

E5GC: 10.5 mm
E5CC: 15.2 mm
E5EC: 18 mm
E5AC: 25 mm


           

The display remains easy to read even from wide viewing angles.

Save space!

The compact and space-saving design of the new E5[]C controller generation requires less panel depth (60 mm)*2, allowing quick snap-mounting and easy installation even under very cramped conditions.
*2 Excluding E5GC/E5DC/E5CC-U

Thanks to the IP66 protection*3 of the front cover, the E5[]C can withstand humid environments and also be cleaned with non-aggressive fluids.
*3 Excluding E5DC/E5CC-U



 

Ratings

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumptionModels with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at
24 VAC or 1.6 W max. at 24 VDC
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W
max. at 24 VDC
Sensor inputTemperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or
140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies
to the E5CC-U only for those manufactured in May 2014 or later.)
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay outputE5CC:
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA (reference value)
E5CC-U:
SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA (reference value)
Voltage output
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 21 mA, with short-circuit
protection circuit
Linear current
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputsE5CC: 3
E5CC-U: 1 or 2 (depends on model)
Output
specifications
SPST-NO relay outputs, 250 VAC, Models with 1 or 2 outputs: 3 A (resistive load), or
Models with 3 outputs: 2 A (resistive load), Electrical life: 100,000 operations, Minimum
applicable load: 10 mA at 5 V (reference value)
Event
input *
Number of inputs2 or 4 (depends on model)
External contact
input
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Transfer
output *
Number of outputs1 (only on models with a transfer output)
Output
specifications
Current output: 4 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., resolution: Approx. 10,000
Setting methodDigital setting using front panel keys
Remote SP input *Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.)
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)
Indication method11-segment digital display and individual indicators
Character height: PV: 15.2 mm, SV: 7.1 mm
Multi SP *Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key
operations, or serial communications.
Bank switchingNone
Other functionsManual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm
functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100%
AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop,
protection functions, extraction of square root, MV change rate limit, logic operations,
temperature status display, simple programming, moving average of input value, and
display brightness setting
Ambient operating
temperature
-10 to 55°C (with no condensation or icing), For 3-year warranty: -10 to 50°C with
standard mounting (with no condensation or icing)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no condensation or icing)
Altitude2,000 m max.
Recommended fuseT2A, 250 VAC, time-lag, low-breaking capacity
Installation environmentInstallation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

* There are no optional functions for the E5CC-U. Refer to Model Number Legend and List of Models on Data Sheet.

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)


Analog input

Input typeCurrentVoltage
Input specification4 to 20 mA0 to 20 mA1 to 5 V0 to 5 V0 to 10 V0 to 50 mV *
Setting rangeUsable in the following ranges by scaling:
-1999 to 9999, -199.9 to 999.9,
-19.99 to 99.99 or -1.999 to 9.999
Set value252627282930

* The range applies to the E5CC-U only for those manufactured in May 2014 or later.

Alarm Types

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1
          parameter is not displayed.
          To use alarm 1, set the output assignment to alarm 1.

Set
value
Alarm typeAlarm output operationDescription of function
When alarm
value X is
positive
When alarm
value X is
negative
0Alarm function
OFF
Output OFFNo alarm

Set the upward deviation in the set point for the
alarm upper limit (H) and the lower deviation in the
set point for the alarm lower limit (L). The alarm is
ON when the PV is outside this deviation range.
2Set the upward deviation in the set point by setting
the alarm value (X). The alarm is ON when the PV
is higher than the SP by the deviation or more.

Set the downward deviation in the set point by
setting the alarm value (X). The alarm is ON when
the PV is lower than the SP by the deviation or more.
4Set the upward deviation in the set point for the
alarm upper limit (H) and the lower deviation in the
set point for the alarm lower limit (L). The alarm is
ON when the PV is inside this deviation range.
5A standby sequence is added to the upper- and
lower-limit alarm (1). *6
6
A standby sequence is added to the upper-limit
alarm (2). *6
7A standby sequence is added to the lower-limit
alarm (3). *6
8
The alarm will turn ON if the process value is larger
than the alarm value (X) regardless of the set point.
9
The alarm will turn ON if the process value is
smaller than the alarm value (X) regardless of the
set point.
10A standby sequence is added to the absolute-value
upper-limit alarm (8). *6
11
A standby sequence is added to the absolute-value
lower-limit alarm (9). *6
12




*4 Set value: 5, Upper- and lower-limit with standby sequence
         For Upper- and Lower-Limit Alarm Described Above *2
      • Case 1 and 2
         Always OFF when the upper-limit and lower-limit hysteresis overlaps.
      • Case 3: Always OFF
*5 Set value: 5, Upper- and lower-limit with standby sequence Always OFF when the upper-limit and lower-limit hysteresis
      overlaps.
*6 Refer to the E5[]C Digital Temperature Controllers User's Manual (Cat. No. H174) for information on the operation of
      the standby sequence.
*7 Refer to the E5[]C Digital Temperature Controllers User's Manual (Cat. No.H174) for information on the loop burnout
      alarm (LBA).
*8 Refer to the E5[]C Digital Temperature Controllers User's Manual (Cat. No. H174) for information on the PV change
      rate alarm.
*9 When heating/cooling control is performed, the MV absolute upper limit alarm functions only for the heating operation
      and the MV absolute lower limit alarm functions only for the cooling operation.
*10 This value is displayed only when a remote SP input is used. It functions in both Local SP Mode and Remote SP
        Mode.
        Remote SP input is supported only for the E5CC.

Characteristics

Indication accuracy
(at the ambient
temperature of 23°C)
E5CC
Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1
Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater)
±1 digit
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
E5CC-U
Thermocouple: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. *1
Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater)
±1 digit
Analog input: ±0.2% FS ±1 digit max.
Transfer output
accuracy
± 0.3% FS max.
Simple transfer output
accuracy
±0.3% FS max.*2
Remote SP Input Type± 0.2% FS ± 1 digit max.
Influence of
temperature *3
Thermocouple input (R, S, B, W, PL II): (±1% of indication value or ±10°C, whichever is
greater) ±1 digit max.
Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit
max. *4
Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater)
±1 digit max.
Analog input: ±1%FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Remote SP input: ±1% FS ±1 digit max.
Influence of voltage *3
Input sampling period50 ms
HysteresisTemperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Proportional band (P)Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I)0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D)0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Proportional band (P)
for cooling
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I) for
cooling
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D) for
cooling
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Control period0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)
Manual reset value0.0 to 100.0% (in units of 0.1%)
Alarm setting range-1999 to 9999 (decimal point position depends on input type)
Influence of signal
source resistance
Thermocouple: 0.1°C/Ω max. (100 Ωmax.)
Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)
Insulation resistance20 MΩ min. (at 500 VDC)
Dielectric strength3,000 VAC, 50/60 Hz for 1 min between terminals of different charge
VibrationMalfunction10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
Resistance10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions
ShockMalfunction100 m/s2, 3 times each in X, Y, and Z directions
Resistance300 m/s2, 3 times each in X, Y, and Z directions
WeightE5CC: Controller: Approx. 120 g, Adapter: Approx. 10 g
E5CC-U: Controller: Approx. 100 g, Adapter: Approx. 10 g
Degree of protectionE5CC: Front panel: IP66, Rear case: IP20, Terminals: IP00
E5CC-U: Front panel: IP50, Rear case: IP20, Terminals: IP00
Memory protectionNon-volatile memory (number of writes: 1,000,000 times)
Setup ToolE5CC: CX-Thermo version 4.5 or higher
E5CC-U: CX-Thermo version 4.61 or higher
Setup Tool portE5CC/E5CC-U top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to
a USB port on the computer. *6
StandardsApproved
standards
UL 61010-1*7, KOSHA certified (some models) *8, Korean Radio Waves Act (Act 10564)
Conformed
standards
EN 61010-1 (IEC 61010-1): Pollution Degree 2, overvoltage category II, Lloyd's standards *9
EMCEMI: EN61326
Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A
Noise Terminal Voltage: EN 55011 Group 1, class A
EMS: EN 61326
ESD Immunity: EN 61000-4-2
Electromagnetic Field Immunity: EN 61000-4-3
Burst Noise Immunity: EN 61000-4-4
Conducted Disturbance Immunity: EN 61000-4-6
Surge Immunity: EN 61000-4-5
Voltage Dip/Interrupting Immunity: EN 61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of
      -100°C max., and U and L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the
      B thermocouple at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a
      temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature
      of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C,
      whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C,
      whichever is greater) ±1 digit max.
*2 However, the precision between 0 and 4 mA for a 0 to 20 mA output is ±1% FS max.
*3 Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage
*4 K thermocouple at -100°C max.: ±10°C max.
*5 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
*6 External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.
*7 The E5CC-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E
      Socket. The P3GA-11 is not certified for UL listing.
*8 Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html
*9 Refer to information on maritime standards in Shipping Standards on Data Sheet for compliance with Lloyd's
      Standards.

USB-Serial Conversion Cable

Applicable OSWindows XP/Vista/7/8
Applicable softwareCX-Thermo version 4.5 or higher (Version 4.61 or higher is required for the E5CC-U.)
Applicable modelsE5[]C-T Series, E5[]C Series, and E5CB Series
USB interface standardConforms to USB Specification 2.0.
DTE speed38400 bps
Connector specificationsComputer: USB (type A plug)
Digital Temperature Controller: Special serial connector
Power supplyBus power (Supplied from USB host controller.) *
Power supply voltage5 VDC
Current consumption450 mA max.
Output voltage4.7 ± 0.2 VDC (Supplied from USB-Serial Conversion Cable to the Digital
Temperature Controller.)
Output current250 mA max. (Supplied from USB-Serial Conversion Cable to the Digital
Temperature Controller.)
Ambient operating
temperature
0 to 55°C (with no condensation or icing)
Ambient operating humidity10% to 80%
Storage temperature-20 to 60°C (with no condensation or icing)
Storage humidity10% to 80%
Altitude2,000 m max.
WeightApprox. 120 g

Windows is a registered trademark of Microsoft Corporation in the United States and or other countries.
* Use a high-power port for the USB port.
Note: A driver must be installed on the computer. Refer to the Instruction Manual included with the Cable for the
          installation procedure.

Communications Specifications

Transmission line connection methodRS-485: Multidrop
CommunicationsRS-485 (two-wire, half duplex)
Synchronization methodStart-stop synchronization
ProtocolCompoWay/F, or Modbus
Baud rate *9600, 19200, 38400, or 57600 bps
Transmission codeASCII
Data bit length *7 or 8 bits
Stop bit length *1 or 2 bits
Error detectionVertical parity (none, even, odd)
Block check character (BCC) with CompoWay/F or CRC-16 Modbus
Flow controlNone
InterfaceRS-485
Retry functionNone
Communications buffer217 bytes
Communications response wait time0 to 99 ms
Default: 20 ms

* The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Communications
    Setting Level.

Communications Functions

Programless
communications
*1
You can use the memory in the PLC to read and write E5[]C parameters, start and stop operation,
etc. The E5[]C automatically performs communications with PLCs. No communications
programming is required.
Number of connected Digital Temperature Controllers: 32 max. (Up to 16 for the FX Series)
Applicable PLCs
OMRON PLCs
CS Series, CJ Series, or CP Series
Mitsubishi Electric PLCs
MELSEC Q Series, L Series, or FX Series (compatible with the FX2 or FX3 (excluding the FX1S))
KEYENCE PLCs
KEYENCE KV Series
Component
Communications
*1
When Digital Temperature Controllers are connected, set points and RUN/STOP commands can be
sent from the Digital Temperature Controller that is set as the master to the Digital Temperature
Controllers that are set as slaves.
Slope and offsets can be set for the set point.
Number of connected Digital Temperature Controllers: 32 max. (including master)
Copying *2When Digital Temperature Controllers are connected, the parameters can be copied from the Digital
Temperature Controller that is set as the master to the Digital Temperature Controllers that are
set as slaves.

MELSEC is a registered trademark of Mitsubishi Electric Corporation.
KEYENCE is a registered trademark of Keyence Corporation.
*1 A Temperature Controller with version 1.1 or higher is required.
      A Temperature Controller with version 2.1 or higher is required for the FX Series or the KV Series.
*2 Both the programless communications and the component communications support the copying.

Current Transformer (Order Separately) Ratings

Dielectric strength 1,000 VAC for 1 min
Vibration resistance 50 Hz, 98 m/s2
Weight E54-CT1: Approx. 11.5 g, E54-CT3: Approx. 50 g
Accessories (E54-CT3 only) Armatures (2)
Plugs (2)

Heater Burnout Alarms and SSR Failure Alarms

CT input (for heater current detection)Models with detection for single-phase heaters: One input
Models with detection for singlephase or three-phase heaters: Two inputs
Maximum heater current50 A AC
Input current indication accuracy± 5% FS ± 1 digit max.
Heater burnout alarm setting range *10.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms *3
SSR failure alarm setting range *20.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms *4

*1 For heater burnout alarms, the heater current will be measured when the control output is ON, and the output will turn
      ON if the heater current is lower than the set value (i.e., heater burnout detection current value).
*2 For SSR failure alarms, the heater current will be measured when the control output is OFF, and the output will turn ON
      if the heater current is higher than the set value (i.e., SSR failure detection current value).
*3 The value is 30 ms for a control period of 0.1 s or 0.2 s.
*4 The value is 35 ms for a control period of 0.1 s or 0.2 s.