Webasto W-bus module S-30 Clear/Erase Errors
After connecting the W-BUS module, turn off the power to the stove and turn
it on again to activate communication.
Webasto
heater that is also started by the Webasto Thermo Test (WTT) Diagnostic Program
on the W-Bus option.
Cleans
up accumulated errors without needing interfaces
diagnostics
or go to a service center.
-press
the button for 3 seconds and the errors are cleared.
Led
indication:
-No light -in standby
-blinking
light -w bus module started
- If the
LED is constantly on, there is a problem with the heater or it is not connected
correctly.
W-bus
S-30 has an outlet for a circulation pump.
Additional
outputs for water pump 12v (can be used at discretion)
- after stopping the stove, the water pump continues to
circulate for 120 seconds
W-bus
module S-30, for Webasto stoves
With
it, you start your stove via w-bus and it becomes autonomous.
Starts
when 12v is supplied.
Stops
when 12v is interrupted.
This
is handy for connecting to:
-remote
module
-sim
controller
-tsk
key
-weekly
timer, etc
The
W-BUS module is an analog signal to digital converter based on W-Bus and is
designed to work with stoves:
Webasto
Thermo Top V
Thermo
Top EVO 2017-2020
Thermo
Top C.
Managed with: W-BUS
V1.4, V1.5, W-BUS v.3.1.(MAZDA 6 2008 ), W-BUS v3.3(VW TOURAN, VW
CADDY, GOLF V, Land Rover 2006-2010),BMW E70 protocol,W-BUS
V4.1,V4.3 EVO protocol, etc.
The controller activates the stove in autonomous mode
without the need for the car computer.
Instruction:
If +12V is not supplied to START and the RESET button is not
pressed, then the LED does NOT light. If 12 volts are supplied to start, then
if everything is OK it starts flashing. After stopping it starts flashing
faster for 120 seconds (to rotate the circulation pump). When the reset button
is pressed for 3 seconds it starts flashing and goes out.
If the LED is constantly on, there is a problem with the heater
or it is not connected correctly.
Error reset.
If the RESET button is pressed for about 3 seconds, the LED
flashes FAST during error clearing. After clearing, the LED goes out.
Enable WTT.
It is necessary to supply constant voltage + 12V to START.
The pump and stove will start. The LED should blink SLOWLY. If you
remove the constant voltage + 12V to START, then the stove will stop and the
pump will continue to work for 2 minutes. At the same time the LED should
flash FAST.
Power supply: 12 v.
Protection included in reverse polarity supply.
W-Bus module
LED indicator
Dimensions: 50 x 30 mm.
The set contains:
W-bus module-1pcs