YUSHI YUT-2600 Digital Ultrasonic Flaw Detector DAC Curve with UT Transducers
阿里详情YUT-2600修改01.jpg
阿里详情YUT-2600修改03.jpg
阿里详情YUT-2600修改04.jpg
阿里详情YUT-2600修改05.jpg阿里详情YUT-2600修改02.jpg
阿里详情YUT-2600修改09.jpg 
 
Features of YUT-2600
Full Screen Display Function The echo display area covers the entire screen, the operator will have a maximal view.
Bulk Storage Up to 1000 data sets can be stored, including waveforms, curves and parameters etc.
The peak or front edge of the echo within the gate.
Echo-echo Thickness Measurement No need of zero calibration , the substrate thickness can be directly measured through the coating.
Peak Memory Show the highest wave of the flaws in real time and record the maximum value of flaws, it is helpful to exact positioning and fast testing of flaws.
Automatic Gain Automatically adjust the gain to the pre-set amplitude height.
Alarming Function Afferent echo /echo loss alarming
Solid Waveform Display Enhancing the waveform visual contrast so the omission will hardly happen during the fast testing.
Real-time Clock Automatically record the date of the stored waveform. 
Display Freezing Capture waveform and acoustic path data, and move the gate to measure echo parameters after freezing.
Flaw Localization Real -time display the sound path S, horizontal X, depth Y, and wave height H. 
Flaw Quantification Real-time display the dB difference & SL values.
Digital Inhibition 0-80%, increasing by 1%, not affecting the linearity and gain.
A、B Gate Two independent gates, monitoring the echo amplitude and the sound path distance. 
DAC Curve Perfect DAC curve functions, enable the curves to change along with the changes of the gain, sound path, and displacement.
Data Communication Communicating with the computer through the RS232 interface to transfer the waveform and data to realize the management of the detection results and the generation and printout of the detection report.
 
Technical Parameters

Item

Index

Item

Index

Working Frequency

(0.5-15)MHz

Sensitivity Excess

55dB(deep Φ2 Flat-bottom hole)

Material Sound Vecocity

(1000-9999) m/s

Definition

26dB

Operation Mode

Pulse echo, double crystal

Dynamic Range

26dB

Pulse Shift

(0-2000)mm

Average Noise Level

≤10%

Probe Zero

(0-99.99)us

Battery Working Time  

9 hours

Gain Control

(0-110)dB,(0.1,1-2,6)dB stepping

Power Supply

12V DC,220V AC

Vertical Linearity Error

≤5%

Dimensions

270mm x190mm x 60mm

Horizontal Linearity Error

≤0.5%

Weight

1.5kg(Without battery)

 
PushAuction