THE
MASS FLOW METER HAS NEVER BEEN USED – BOXED WITH CALIBRATION CERTIFICATE
DETAILS
MFM D
– 6230
SN 5105-6979D
FLOW 65Lt/min
GAS
NATURAL (CH4)
WORKING
P 0.050 BAR GAUGE
P MAX
10 BAR
POWER
24 VDC
OUT
0-5 VOLT
SEALS
VITON
COMES
WITH
INLET
FLOW STRAIGHTENER PIPE – 240mm LONG / 10mm DIAMETER
OUTLET
FLOW STRAIGHTENER PIPE – 240mm LONG / 10mm DIAMETER
ELECTRICAL
CONNECTOR 5-PIN WITH A SHORT LENGTH OF WIRE
Proven
direct inline CTA sensor (no bypass)
Compact,
rugged design (IP65, dust and waterproof)
Very low
pressure drop
Less
sensitivity to humidity or dirt
Bronkhorst model D-6320 Mass
Flow Meters (MFMs) are suited for precise measurement of flow at operating
pressures between vacuum and 10 bar (Aluminium) or 20 bar (Stainless Steel).
The MFM consists of a proven inline thermal (CTA) mass flow sensor and a microprocessor
based pc-board with signal and fieldbus conversion and a PID controller for
optional mass flow control by means of a separately mounted control valve. The
instrument is IP65 compliant and can optionally be equipped with a modern,
multi-functional and multi-colour display, with operator buttons on the
instrument.
The digital MASS-STREAM series is characterized by a high degree of signal
integrity and, as an option, up to 8 calibration curves of different gases and
process conditions can be memorized in the instrument. In addition to the
standard RS232 output the instruments also offer analog I/O. As an option, an
on-board interface can be mounted to provide CANopen®, DeviceNet™, PROFIBUS DP,
PROFINET, Modbus RTU or FLOW-BUS (other on request) protocols.
Measurement
/ control system
Flow range (intermediate ranges
available)
min. 0,05…1 ln/min
max. 0,35…7 ln/min
(based on N2)
Accuracy (incl. linearity) (based
on actual calibration)
± 1,0 % RD plus ±
0.5% FS (at calibration conditions)
Repeatability
< 0,2 % FS
Turndown ratio
1:20
Response time (sensor)
approx. 0,3 sec.
Operating temperature
0 … 50 °C
Temperature sensitivity
± 0,2% Rd/°C (Air)
Pressure sensitivity
± 0,3 %
Leak integrity, outboard
tested < 2 x 10-8 mbar
l/s He
Attitude sensitivity
at 90° deviation from horizontal
max. error 0,2 % at 1 bar typical N2
Warm-up time
Mechanical
parts
Sensor
Stainless steel SS 316 (AISI
316L)
Pressure rating (PN)
10 bar g for instrument body in
aluminium,
20 bar g for instrument body in stainless steel SS 316
Process connections
G1/4" / compression type or
face seal (VCR/VCO) couplings
Seals
standard: Viton®;
options: EPDM, Kalrez® (FFKM), FDA and USP Class VI approved compounds
Ingress protection
IP65
Instrument body
Aluminium AL 50ST/51ST (anodised)
or stainless steel SS 316
Sieves and rings
Electrical
properties
Power supply
+15 … 24 Vdc ±10%
Max. power consumption
Supply
15 V
24 V
Basic model
115 mA
85 mA
Add. for fieldbus
80 mA
50 mA
Add. for display
30 mA
20 mA
Analog output
0…5 (10) Vdc or 0 (4)…20
mA sourcing output)
Digital communication
Electrical
connection
Analog/RS232
8 DIN (male);
PROFIBUS DP
bus: 5-pin M12 (female);
power: 8 DIN (male)
CANopen® / DeviceNet™
5-pin M12 (male)
Modbus RTU / FLOW-BUS
5-pin M12 (male)
Modbus TCP / EtherNet/IP /
POWERLINK
bus: 2 x 5-pin M12 (female)
(in/out);
power: 8 DIN (male);
EtherCAT®/ PROFINET
Please ask for the cost for posting outside
the