Heater
    Uf---------------------------------------10 V
    If----------------------------------------3.25 A
     
    Maximum Rating
    Ua----------------------------------1250 V
    Pa-------------------------------75 W
    Pout(max.sig)--------------------------150 W
    Ia(max)------------------------------120 mA;
     
    Direct Interelectrode Capacitances
    Input----------------------------------6 PF
    output----------------------------------4.5 PF
    Grid to plate----------------------------------14.5 PF
     
    Static parameter
    Ua--------------------------------------1250 V
    —Ug-------------------------------------200 V
    Ia---------------------------------------80 mA
    Gm--------------------------------------3 mA/V
    ri----------------------------------------1.7 KΩ
    u----------------------------------------5
    RL---------------------------------------3.4 KΩ
    Ug(pk)------------------------------------69 V
    Pout-------------------------------------15 W
     
    Recommended Operating Conditions(reference value)
    class A1 .single tube:
    Ua-----1000 1000 1250 V
    —Ug--- 145 155 209 V
    RL-----6 9 16 KΩ
    Ia------90 65 52 mA
    Gm-----3.1 — — mA/V
    Ug(pk)--— 110 148 V
    ri------1.7 1.9 2.1 KΩ
    Pout----24 21 24 W
     
    Push-pull.class AB1:
    Ua------------------ 800 1000 1000 1250 V
    —Ug---------------- 125 170 175 225 V
    RL------------------ 4.5 4.6 4.6 6.6 KΩ
    Ia--------------------80 70 40 40 mA
    Ug(pk)----------------177 240 — — V
    Ia(mAx.sig)---------170 230 230 240 mA
    Pout----------------40 75 75 115 W

Packing :