FIGARO Air Quality Sensor TGS2602 

Application
Air cleaners
Ventilation control
Air quality monitors
VOC monitors
Odor monitors

Features
High sensitivity to VOCs and odorous gases
Low power consumption
High sensitivity to gaseous air contaminants
Long life
Uses simple electrical circuit
Small size

Specifications
Model number: TGS2602-B00
Sensing principle: MOS type
Standard package: TO-5 metal can
Target gases: Air contaminants(VOCs, ammonia, H2S, etc.)
Typical detection range: 1 ~ 30ppm of EtOH
Standard circuit conditions
Heater voltage VH: 5.0±0.2V AC/DC
Circuit voltage VC: 5.0±0.2V DC Ps≤15mW
Load resistance RL: variable 0.45kΩ min.
Electrical characteristics under standard test conditions
Heater resistance RH:  approx 59Ω at room temp.(typical)
Heater current IH: 56±5mA
Heater power consumption PH: 280mW
Sensor resistance RS:  10kΩ ~ 100kΩ in air
Sensitivity(change ratio of Rs): 0.08~0.5 Rs (10ppm of EtOH)/Rs air
Standard test conditions
Test gas conditions:  normal air at 20±2˚C, 65±5%RH
Circuit conditions:  Vc = 5.0±0.01V DC VH = 5.0±0.05V DC
Conditioning period before test: 7 days

Package
1 Pcs