23 Pcs Large Dental Implant Broken Screw Remover Kit Surgical Tools Instrument 

Screw Remover Kit is a surgical tool developed in order safely and quickly to remove screws that have become fractured inside an implanted Fixture for va
rious reasons. After removing the Screw, a new Abutment may be connected to the Fixture.Remove Fractured Screw, Screw Remover
No Worries About Fractured Screw.

Included:
4 x Claw Drills - 3 x Perfect Guides - 3 x reverse Drills - 3 x Screw Remover Drills
3 x Internal Guides - 3 x External Guides - 1 x Conical Guide
1 x Shank Driver - 1 x Perfect Guide Hand Driver
1 x SR Driver holder

Features
Remove fractured screw without damaging the fixture or pulling out the fixture.
Fractured screw can be removed in 3 minutes.
Various implant system can be applied to Neo Screw Remover kit.
Screw with excessive torque can be removed with ratchet.

Screw Remover Kit contains:
1. Claw
This is a surgical tool that removes a screw that has become fractured inside the Fixture.
After selecting the size that is appropriate for the size of the screw that is to be removed, it must be used by connecting a guide to the Fixture (Conical/Internal/External Guide). Then it is connected to the Shank Driver, and the fractured screw can be removed by rotating by hand in the reverse direction. If the fractured screw cannot be removed using the Claw, it must be removed using the Reverse Drill and the Screw Remover.

Product NameFractured Screw sizeProduct NameFractured Screw size
Claw Drill /CD16M1.6Claw Drill / CD20M2.0
Claw Drill / CD18M1.8Claw Drill / CD25M2.5

2. Reverse Drill
 This is a tool that creates a hole on the fractured face of the Screw that will be used by the Screw Remover.
  After selecting the appropriate Reverse Drill for the size of the screw that needs to be removed, it must be used by connecting a guide for the fixture (Perfect/ Conical/Internal/External Guide). The depth of the drill can be adjusted from 1 mm to 3 mm, because the Drill body has markings.

Product NameDiameter(Ø)Fractured Screw size
Reverse Drill / RCD10Ø 1.0M1.8
Reverse Drill / RCD12
Ø 1.2M1.8
Reverse Drill / RCD14
Ø 1.4M1.8


 - The removal of an M1.6 size Screw Should utilize the Claw.
 - Although diff erent manufacturers produce diff erent sizes of abutment screws, except in rare cases, typically they utilize screws of Size M1.6, M1.8, M2.0, or M2.5. (‘M’ stands for a metric screw. The number indicates the external size of the screw. For example, “M1.6 Screw” indicates that it is a metric screw the external diameter of  Which is 1.6 mm).

3. Screw Remover
 - This is a device that removes a fractured screw. Insert a Screw Remover that is appropriate for the size of the hole that has been formed using the Reverse Drill and rotate at a low speed (at or below 80 rpm) in the reverse direction.
 - The Screw Remover was designed in a tapered shape so as to increase, as it turns, the amount of friction, which is necessary to loosen the Screw.

Product NameDiameter (Ø)Perfect Guide Fractured Screw size
Screw Remover / SR10
Ø 1.0M1.8
Screw Remover / SR12
Ø 1.2M2.0
Screw Remover / SR14
Ø 1.4M2.5


4. Shank Driver
 - This is a surgical tool that was designed to be connected to the Screw Remover to allow the use of the hand, Torque Wrench, or Ratchet.

Product NameStandardApplicable Products
SHD00for Hand or Ratchet

Screw Remover

(SR10, SR12, SR14)



5. Perfect Guide & PG Hand Driver
 - The Perfect Guide acts as a Guide for the Reverse Drill. It is used when the screw is fractured at the lower part of the female screw inside the Fixture. It is connected to PG Hand Driver and is directly applied to the Fixture female Screw.
 - The Perfect Guide can be safely used because it has a stop structure inside that prevents the Reverse Drill from drilling more than 2 mm.

6. Conical, Internal, External Guide
 - They act as the Guide when using the Reverse Drill. They are used when the Perfect Guide cannot be used, or if the screw was fractured at a location deeper than 2 mm into the lower part of the female screw inside the Fixture.
 - The Guide appropriate for connecting to the Fixture must be selected.

7. SR Driver Holder
This can be easily affixed to the Fixture by connecting it to the 3.5 Double Hex part of the Conical, Internal, or External Guide.

Manufactured from High Grade Stainless Steel - Highly Polished

Autoclave able / Sterilize able

Designed to Perfectly Fit the Hands - Work with Comfort!
Reliable and Durable
Handcrafted to precise dimensions

Brand New (The Instruments Are Made With Superb Perfection And Excellent QualityPremium Grade Stainless Steel )

All products are excellent quality - All pictures are of actual items

BRITISH STANDARD QUALITY- BUY WITH CONFIDENCE

We do not compromise on quality

100% BUYER SATISFACTION GUARANTEED


Request to our Customers

Please do not leave us a negative or neutral feedback.

If you have any issue with product, we will be more than happy to help you.

RETURN POLICY

 We assure you that you will be happy with your purchase. If in case you find any quality and fitting issues Kindly Contact Us At  VIA E bay and we will sort it out for you. We want you to be delighted every time you shop with us. 

• Item must be returned unused in its original packaging.

 • Item must not be damaged or show signs of excessive wear or abuse.

 • Customers are responsible for delivery charges back to us unless the item is faulty.

POLICY:

 We assure you that you will be happy with your purchase. If in case you find any quality and fitting issues Kindly Contact Us At  DENTRA INSTRUMENTS we will sort it out for you. We want you to be delighted every time you shop with us. Occasionally though, we know you may want to return item(s). When returning item(s) they must be returned in the following conditions; 

• Item(s) must be returned unused in its original packaging.

 • Item(s) must not be damaged or show signs of excessive wear or abuse.

 • Item(s) must be packaged sufficiently to avoid damage in transit.

 • Customers are responsible for delivery charges back to us unless the item(s) is faulty.

 • Please ensure that item(s) is sent by either recorded delivery or courier. We cannot except any liability for goods lost in transit.

 • Item(s) must be shipped back within 14 days of purchase in order for us to issue a refund or exchange.

PLEASE NOTE!

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."


DENTRA INSTRUMENTS
31 EXETER ROAD
E17 7QJ - LONDON
UNITED KINGDOM

100% Money Back Guarantee