Zero Anti-Freeze Valve 1" Male x 1" Female Swivel

The patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.

Building regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.

The Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance: 

Without Insulation

Water Discharge Temperature = 2.49°C Time taken to begin discharge = 1 hour 4mins

With Insulation
Water Discharge Temperature = 2.03°C Time taken to begin discharge = 4hour 3mins