Zero Anti-Freeze Valve 1" Male x 1" Female Swivel
The patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly
and accurately react to the water temperature in the heat pump circuit and do not
need the influence of the ambient temperature to operate.
Building regulations Part L states that all external fittings on an Air Source Heat Pump
System must be fully insulated to reduce heat loss and maintain system efficiency. Inta
Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at
the same temperature even when a system is correctly insulated.
The Inta Zero Anti-Freeze valves have been Independently tested using a controlled
Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to
demonstrate the possibility of insulating the Inta Zero Valve without affecting the
performance:
Without Insulation
Water Discharge Temperature = 2.49°C
Time taken to begin discharge = 1 hour 4mins
With Insulation
Water Discharge Temperature = 2.03°C
Time taken to begin discharge = 4hour 3mins
- Max Inlet Pressure (static): 10 Bar
- Medium: Water
- Sensitivity: +/-1°C
- Opening Temperature: 3°C
- Working Temperature Range: 0 - 65°C
- Ambient Temperature Range: -30 - 60°C
- Kv: 64m³/h
- Max Discharge Flow Rate @ 3 Bar: 1.5 L/H
- Closing Temperature: 4°C
- Valve Body: UNI EN 12165 CW617N
- Spring: Stainless Steel
- Internal Parts: UNI EN 12164 CW617N
- Internal Seals: EPDM PEROX