Brocade MLXe-8 BR-MLXE-8-MR2-M-AC 8-Slot Chassis + Modules

Part Number: 80-1005561-02

Model: BR-MLXE-8-MR2-M-AC

In Good Condition, Full Working Order

Included

  • 1 x Brocade MLXe-8 BR-MLXE-8-MR2-M-AC 8-Slot Chassis
    • 2 x BR-MLX-MR2-M Management Modules
    • 2 x NI-X-HSF Switch Fabric Modules
    • 1 x NI-MLX-10GX8-M 8-Port 10GbE Module With:
      • 5 x 10Gb SFP Modules
    • 1 x BR-MLX-1GCX24-X 24-Port 10/100/1000Base-T Copper Module
    • 4 x AWF-1DC-1800W 1800W Power Supply PSU

Description

The Brocade MLX Series of advanced routers delivers unprecedented scale and performance, high reliability, and cost-saving operational efficiency for the world's most demanding service provider and enterprise networks. With OpenFlow support in true hybrid mode, the Brocade MLX Series delivers industry-leading 10 GbE and 100 GbE density for software-defined networks in conjunction with traditional routing, providing flexible flow control to respond to dynamic traffic patterns and address business needs.

Multiservice IP/MPLS SDN Routers

The way organizations communicate and conduct business has changed dramatically in the past decade. Services such as high-definition video streaming, cloud services, and anytime/anywhere mobile connectivity not only consume an enormous amount of network capacity, but also create a greater degree of complexity for network operations. As a result, today's network planners are seeking solutions that provide the right mix of scalability, performance, programmability, and operational simplicity.

The Brocade MLX Series of high-performance routers, which includes Brocade MLXe Core Routers, is designed to meet these requirements and many others. Built with a state-of-the-art, sixth-generation, network processor-based architecture and terabit-scale switch fabrics, the Brocade MLX Series provides a rich set of high-performance Layer 2/3, IPv4, IPv6, Multiprotocol Label Switching (MPLS), wire-speed encryption, and Software-Defined Networking (SDN). As a result, these routers address the diverse needs in environments that include the data centers of service provider, enterprise, and public sector organizations; service provider transit and Internet Exchange Points (IXPs); research and education networks; enterprise and public sector campuses; and mobile 4G/LTE service providers.

Highlights

  • Scalable multiservice IP/MPLS, SDN-enabled routers in 4-, 8-, 16-, and 32-slot chassis options
  • Fully distributed, non-blocking, and programmable architecture with up to 15.36 Tbps fabric capacity for maximum performance and investment protection
  • 64 100 GbE, 128 40 GbE, 768 10 GbE, and 1,536 1 GbE ports in a single router
  • Wire-speed forwarding performance for all software features, including Ethernet, VLAN, IPv4, IPv6, MPLS, VPLS, IPsec, MACsec, and OpenFlow capabilities
  • High-availability design with redundant management modules, switch fabrics, power supplies, and fans; hitless failover; hitless software upgrades; and non-stop routing
  • Delivers integrated hardware support for OpenFlow 1.3 in the industry's only true hybrid port mode, enabling SDN to seamlessly interwork with existing network forwarding
  • Ideal for applications in data center core and interconnects, Wide Area Networks (WANs), and campus cores

Built for Fail-Safe, Nonstop Networking

  • Advanced, redundant switch fabric ensures very high availability
  • Operates at peak performance even during switch-fabric module failure
  • During a failure, the system will automatically tune to the remaining fabric capacity

Superior Data Security and Performance

  • Total system performance: Over 1 Tbps
  • Supports up to 128 ports of 10 GbE
  • Delivers embedded IPsec encryption at wire speed
  • Supports Suite B (one of the strongest cryptographic suites for IPsec) in hardware


























Specifications:

 
MLXe-8

System Summary
Interface slots
8

Switch fabric capacity
3.84 Tbps

Data forwarding capacity
3.2 Tbps

Packet routing performance
2.38 billion pps

Maximum 100 GbE ports
16

Maximum 40 GbE ports
32

Maximum 10 GbE ports
192

Maximum 1 GbE ports
384

Height (inches/rack units)
12.21 in./7RU

Switch fabric redundancy
1:1

Management module redundancy
N+1

Power supply redundancy
1+1

Airflow
Side to back

Power
Maximum DC power consumption (W)
4,060

Maximum AC power consumption (W) (100-240 VAC)
4,060

Maximum thermal output (BTU/HR)
13,858

Mechanical
Dimensions (WxHxD)17.20 in. X 12.21 in. X 24.0 in.
(43.69 cm X 31.01 cm X 60.96 cm)


Weight
171 lb (78 kg)

Environmental
Operating Temperature0°C to 40°C (32°F to 104°F)
Relative Humidity5% to 90%, at 40°C (104°F), non-condensing
Operating Altitude6600 ft (2012 m)
Storage Temperature−25°C to 70°C (−13°F to 158°F)
Storage Humidity95% maximum relative humidity, non-condensing
Storage Altitude15,000 ft (4500 m) maximum
Regulatory Compliance and Safety Approvals
Safety Agency Approvals
  • CAN/CSA-C22.2 No. 60950-1-3
  • UL 60950-1
  • IEC 60950-1
  • EN 60950-1 Safety of Information Technology Equipment
  • EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User's Guide
  • EN 60825-2 Safety of Laser Product—Part 2: Safety of Optical Fibre Communication Systems
Electromagnetic Emission
  • ICES-003 Electromagnetic Emission
  • FCC Class A
  • EN 55022/CISPR-22 Class A/VCCI Class A
  • AS/NZS 55022
  • EN 61000-3-2 Power Line Harmonics
  • EN 61000-3-3 Voltage Fluctuation and Flicker
  • EN 61000-6-3 Emission Standard (supersedes EN 50081-1)
Immunity
  • EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1)
  • EN 55024 Immunity Characteristics. Supersedes:
    • EN 61000-4-2 ESD
    • EN 61000-4-3 Radiated, radio frequency, electromagnetic field
    • EN 61000-4-4 Electrical fast transient
    • EN 61000-4-5 Surge
    • EN 61000-4-6 Conducted disturbances induced by radiofrequency fields
    • EN 61000-4-8 Power frequency magnetic field
    • EN 61000-4-11 Voltage dips and sags
TELCO NEBS/ETSIDesigned to meet the following specifications (formal testing under way):
  • Telcordia GR-63-CORE NEBS Requirements: Physical Protection
  • Telcordia GR-1089-CORE EMC and Electrical Safety
  • Telcordia SR-3580 Level 3
  • ETSI ETS 300-019 Physical Protection
    — Part 1-1, Class 1.1, Partly Temperature Controlled Storage Locations
    — Part 1-2, Class 2.3, Public Transportation
    — Part 1-3, Class 3.1, Temperature Controlled Locations (Operational)
  • ETSI ETS 300-386 EMI/EMC
Power and Grounding
  • ETS 300 132-1 Equipment Requirements for AC Power Equipment Derived from DC Sources
  • ETS 300 132-2 Equipment Requirements for DC Powered Equipment
  • ETS 300 253 Facility Requirements
Physical Design and Mounting19-inch rack mount supporting racks compliant with:
  • ANSI/EIA-310-D
  • ETS 300 119
  • GR-63-CORE Seismic Zone 4 Table top
Environmental Regulatory Compliance
  • EU 2002/95/EC RoHS (with lead exemption)
  • EU 2002/96/EC WEEE
Network Equipment Building Standards (NEBS)
  • GR-1089-CORE NEBS EMC and Safety
  • GR-63 CORE: NEBS Physical Protection
  • SR-3580: NEBS Criteria Levels (Level 3)

Boot Log:

NetIron MLX-8 Router#show version

System Mode: MLX

Chassis: MLXe 8-slot (Serial #: BGB2525J00X,  Part #: 40-1000362-04)

NI-X-HSF Switch Fabric Module 1 (Serial #: BEU0422J01L,  Part #: 60-1001588-14)

FE 1: Type fe600,  Version 1

FE 3: Type fe600,  Version 1

Switch Fabric Module 1 Up Time is 6 minutes 59 seconds

NI-X-HSF Switch Fabric Module 2 (Serial #: BEU0422J03Y,  Part #: 60-1001588-14)

FE 1: Type fe600,  Version 1

FE 3: Type fe600,  Version 1

Switch Fabric Module 2 Up Time is 6 minutes 59 seconds

==========================================================================

SL M1: BR-MLX-MR2-M Management Module Active (Serial #: BVP0414J00R, Part #: 60-1002374-06):

Boot     : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Apr 16 2013 at 11:17:16 labeled as xmprm05400d

 (521484 bytes) from boot flash

Monitor  : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Apr 16 2013 at 11:16:38 labeled as xmb05400d

 (528036 bytes) from code flash

IronWare : Version 5.4.0dT163 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Jul  3 2013 at 13:12:20 labeled as xmr05400d

 (8879695 bytes) from Primary

Board ID : 00 MBRIDGE Revision : 37

1666 MHz Power PC processor 7448 (version 8004/0202) 166 MHz bus

512 KB Boot Flash (MX29LV040C), 128 MB Code Flash (MT28F256J3)

4096 MB DRAM INSTALLED

4096 MB DRAM ADDRESSABLE

Active Management uptime is 6 minutes 59 seconds

==========================================================================

SL M2: BR-MLX-MR2-M Management Module Standby (Serial #: BVP0418J019, Part #: 60-1002374-06):

Boot     : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Apr 16 2013 at 11:17:16 labeled as xmprm05400d

 (521484 bytes) from boot flash

Monitor  : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Apr 16 2013 at 11:16:38 labeled as xmb05400d

 (528036 bytes) from code flash

IronWare : Version 5.4.0dT163 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Jul  3 2013 at 13:12:20 labeled as xmr05400d

 (8879695 bytes) from Primary

Board ID : 00 MBRIDGE Revision : 37

1666 MHz Power PC processor 7448 (version 8004/0202) 166 MHz bus

512 KB Boot Flash (MX29LV040C), 128 MB Code Flash (MT28F256J3)

4096 MB DRAM INSTALLED

4096 MB DRAM ADDRESSABLE

Standby Management uptime is 6 minutes 21 seconds

==========================================================================

SL 1: NI-MLX-10Gx8-M 8-port 10GbE (M) Module (Serial #: BEQ0426J02N, Part #: 60-1001587-16)

(LID: dgsFJHLlFHp)

Boot     : Version 5.4.0dT175 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Apr 16 2013 at 11:17:42 labeled as xmlprm05400d

 (520141 bytes) from boot flash

Monitor  : Version 5.4.0dT175 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Apr 16 2013 at 11:18:06 labeled as xmlb05400d

 (527544 bytes) from code flash

IronWare : Version 5.4.0dT177 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.

Compiled on Jul  3 2013 at 13:18:48 labeled as xmlp05400d

 (7234085 bytes) from Primary

FPGA versions:

Valid PBIF Version = 2.00, Build Time = 3/7/2013 14:03:00

 

Valid XPP Version = 4.18, Build Time = 2/5/2013 13:32:00

 

X10G2MAC 0

X10G2MAC 1

X10G2MAC 2

X10G2MAC 3

1333 MHz MPC 8541 (version 8021/0022) 533 MHz bus

512 KB Boot Flash (MX29LV040C), 64 MB Code Flash (MT28F256J3)

1024 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM

PPCR0: 512K entries CAM, 8192K PRAM, 2048K AGE RAM

PPCR1: 512K entries CAM, 8192K PRAM, 2048K AGE RAM

LP Slot 1 uptime is 6 minutes 19 seconds

==========================================================================

All show version done

NetIron MLX-8 Router#show license

Index   Package Name              Lid          Slot    License Type    Status     License Period

1       MLX-1Gx24-X-Upgrade       dpcFJGHlFGm          normal          invalid    unlimited

NetIron MLX-8 Router#show chassis

*** MLXe 8-slot Chassis ***

 

---POWERS ---

Power 1: (     23-00001 BMG2M12J3XF  - AC 1800W): Installed (OK)

Power 2: (     23-00001 BMG2M12J3TS  - AC 1800W): Installed (OK)

Power 3: (     23-00001 BMG2M17J4JS  - AC 1800W): Installed (OK)

Power 4: (     23-00001 BMG2M17J4JG  - AC 1800W): Installed (OK)

Total power budget for chassis = 7200 W

Total power used by system core = 832 W

Total power used by LPs = 406 W

Total power available = 5962 W

Slot Power-On Priority and Power Usage:

Slot1 pri=1 module type=NI-MLX-10Gx8-M 8-port 10GbE (M) Module power usage=246W

Slot3 pri=1 module type=BR-MLX-1GCx24-X 24-port 10/100/1000Base-T Copper Module power usage=160W

 

--- FANS ---

Back fan A-1: Status = OK, Speed = LOW (50%)

Back fan A-2: Status = OK, Speed = LOW (50%)

Back fan B-1: Status = OK, Speed = LOW (50%)

Back fan B-2: Status = OK, Speed = LOW (50%)

 

--- TEMPERATURE READINGS ---

Active Mgmt Module: 35.0C 47.875C

Standby Mgmt Module: 36.250C 49.500C

SFM1: FE1:36.500C FE2:36.500C FE3:36.500C

SFM2: FE1:38.125C FE2:38.125C FE3:38.125C

SFM3: not present

LP1 Sensor1: 35.750C

LP1 Sensor2: 41.0C

LP1 Sensor3: UNUSED

LP1 Sensor4: 34.125C

LP1 Sensor5: 45.625C

LP1 Sensor6: UNUSED

LP1 Sensor7: UNUSED

Fans are in auto mode (current speed is LOW (50%)). Temperature monitoring poll period is 60 seconds.

 

--- MISC INFO ---

Backplane EEPROM MAC Address:  cc4e.2418.5d00

NetIron MLX-8 Router#show module

Module                                                      Status                       Ports    Starting MAC

M1 (left ):BR-MLX-MR2-M Management Module                   Active

M2 (right):BR-MLX-MR2-M Management Module                   Standby(Ready State)

F1: NI-X-HSF Switch Fabric Module                           Active

F2: NI-X-HSF Switch Fabric Module                           Active

F3:

S1: NI-MLX-10Gx8-M 8-port 10GbE (M) Module                  CARD_STATE_UP                8        cc4e.2418.5d00

S2:

S3: BR-MLX-1GCx24-X 24-port 10/100/1000Base-T Copper Module CARD_STATE_INTERACTIVE       0        cc4e.2418.5d60

(S3: Configured as invalid module)

S4:

S5:

S6:

S7:

S8:

NetIron MLX-8 Router#


VAT @ 20% INCLUDED IN PRICE - VAT INVOICE PROVIDED
£3500 excluding VAT

VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE OF THE UK

CS 205337 205336 dup .com