Shape / Structure | Enclosed Limit switches |
Service life | General type |
Operating mechanism | Snap action |
Actuator | Sealed roller plunger |
Frequency | 50/60 Hz |
Switching mechanism | Self-reset mechanism |
Contact configuration | Single-Pole, Double-Throw type |
Contact form | SPDT |
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2.5 A (NC) 1.25 A (NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC, Inductive load: 10A (NC) 10A (NO), Motor load: 5A (NC) 2.5A (NO) Rated voltage: 250 VAC, Inductive load: 10A (NC) 10A (NO), Motor load: 3A (NC) 1.5A (NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 8 VDC, Resistive load: A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 14 VDC, Resistive load: A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 30 VDC, Resistive load: A (NC) 6 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 125 VDC, Resistive load: A (NC) 0.5 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO) Rated voltage: 250 VDC, Resistive load: A (NC) 0.25 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO) |
Ratings (DC): Inductive load | Rated voltage: 8 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load : 5 A (NC) 2.5 A (NO) Rated voltage: 14 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load : 5 A (NC) 2.5 A (NO) Rated voltage: 30 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load : 5 A (NC) 2.5 A (NO) Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load : 0.05 A (NC) 0.05 A (NO) Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load : 0.03 A (NC) 0.03 A (NO) |
Explanation | The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. |
Inrush current | NC: 30 A NO: 15 A |
Protective circuit | Classification of protection against electric shock: Class II Short-circuit protective device: 10 A fuse type gG (IEC269) Switch category: D (IEC335) |
Ambient temperature | Operating: -10 to 80 ℃ |
Ambient humidity | Operating: 35 to 95 % RH |
Characteristics |
Permissible operating speed | 0.05 mm/s to 0.5 m/s |
Permissible operating speed (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating speed (Electrically) | 20 operations / 1 minute Max. |
Contact resistance | 15 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) |
Insulation resistance | Between each terminal of the same polarities: 100 MOhm Min. Between live-metallic part and ground: 100 MOhm Min. Between each terminal and non-live-metallic part: 100 MOhm Min. (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: 1,000 VAC Between live-metallic part and ground: 2,000 VAC Betweeneachterminalandnon-live-metallicpart: 2,000 VAC |
Durability (Mechanically) | 10,000,000 operations Min. (No load) * When operate the actuator with the specified value of the Over Travel. (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 500,000 operations Min. * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Pollution degree | 3 (EN60947-5-1) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
Degree of protection | IEC60529 (JEM): IP67 |
Applicable standard (UL) | Standard No.: UL508 File number: E76675 |
Applicable standard (CSA) | Standard No.: C22.2 NO.14 File number: LR45746 |
Applicable standard (TUV) | Standard No.: EN60947-5-1 File number: J50041904 |
Applicable standard (CCC (CQC) ) | Standard No.: GB14048.5 File number: 2003010303077620 |
Applicable standard (EC Directive (Low Voltage Directive) ) | 2006/95/EC |
Mounting specification | Side mounting |