Inductive sensor NJ2-12GM-N-V1c
Technical Data
General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance sn 2 mm
Installation flush
Assured operating distance sa 0 ... 1.62 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type 2-wire
Nominal ratings
Nominal voltage Uo 8.2 V (Ri approx. 1 kΩ)
Operating voltage UB 5 ... 25 V
Switching frequency f 0 ... 2000 Hz
Hysteresis H 3 %
Suitable for 2:1 technology yes , Reverse polarity protection diode not required
Current consumption
Technical Data
Measuring plate not detected ≥ 3 mA at nominal voltage
Measuring plate detected ≤ 1 mA at nominal voltage
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
MTTFd 5887 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Standards EN IEC 60947-5-2
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0037X
Equipment protection level Gb IECEx PTB 11.0037X
Equipment protection level Da IECEx PTB 11.0037X
Equipment protection level Mb IECEx PTB 11.0037X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2048 X
Equipment protection level Gb PTB 00 ATEX 2048 X
Equipment protection level Da PTB 00 ATEX 2048 X
UL approval cULus Listed
Load Type: General Purpose
Circuitry: Class 2 Power Source
Enclosure Type Rating: Type 1
Supply/Switching Voltage: 8.2 V DC
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0452
CCC approval
Hazardous Location 2020322315002255
CML approval on request
ANZEx 18.3018X
KCC approval
Hazardous Location 19-AV4BO-0227
Marine approval DNVGL TAA00001A5
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection type Connector plug
Housing material Stainless steel 1.4305 / AISI 303
Sensing face PBT
Degree of protection IP67
Connector
Threading M12 x 1
Number of pins 4
Dimensions
Length 50 mm
Diameter 12 mm
General information
Scope of delivery 2 self locking nuts in scope of delivery
Use in the hazardous area see instruction manuals