(English item description below)
Artikelzustand
Die Festplatte ist gebraucht, aber in sehr gutem Zustand. Smart-Werte finden sich untenstehend.
Die Bilder zeigen die angebotene Ware. Der Versand erfolgt sicher gepolstert und ausschliesslich per DHL.
Sie erhalten mit der Ware eine Rechnung und ein Jahr Gewährleistung. Der Artikel ist gem. §25a UStG differenzbesteuert, die Mehrwertsteuer kann und darf daher auf der Rechnung nicht separat ausgewiesen werden.
Lieferumfang
- Seagate Exos X16 16 TB HDD ST16000NM001G, Seriennummer ZL2NX5RX
Item condition
The disc has been used, but is in very good condition. SMART data values can be found below.
The images show the actual item that is for sale. Well protected shipping within the EU by DHL.
The item will be delivered with an invoice in your name and comes with 1 year limited seller’s warranty. Due to special tax treatment applicable for used goods (§25a UStG), VAT (sales tax) cannot be reported separately on the invoice. Also, it is not possible to deduct VAT, even if you are a commercial buyer with a valid VAT ID.
Delivery contents
- Seagate Exos X16 16 TB HDD ST16000NM001G, serial number ZL2NX5RX
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-7.0.0-28-generic] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Exos X16
Device Model: ST16000NM001G-2KK103
Serial Number: ZL2NX5RX
LU WWN Device Id: 5 000c50 0e3f5bad2
Firmware Version: SN04
User Capacity: 16,000,900,661,248 bytes [16.0 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database 7.5/5706
ATA Version is: ACS-4 (minor revision not indicated)
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Aug 14 12:22:54 2026 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x82)Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0)The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 567) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003)Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01)Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: (1441) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x70bd)SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 078 064 044 Pre-fail Always - 0/56622682
3 Spin_Up_Time 0x0003 090 089 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 141
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 088 060 045 Pre-fail Always - 0/655232048
9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 19630
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 132
18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 099 000 Old_age Always - 0 1 2
190 Airflow_Temperature_Cel 0x0022 071 056 040 Old_age Always - 29 (Min/Max 27/29)
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 68
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 948
194 Temperature_Celsius 0x0022 029 044 000 Old_age Always - 29 (0 21 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 17891h+38m+58.309s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 94639137393
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1914788750938
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 19630 -