8" Patient Monitor ICU CCU Vital Sign For Hospital NIBP, SPO2, PR,TEMP (PM80B )
Standard Parameters:
NIBP, SPO2, PR,TEMP
Features:
1.Compact and flexible appearance.
2.Simple and convenient operation, which is applicable for community medical treatment and family ect.
3.8 inch high resolution color TFT display.
4.Adjustable audible and visual alarms.
5.Built-in rechargeable lithium battery for uninterrupted monitoring.
Technique Specification:
1.SPO2
①Measuring Range: 0 ~ 100 %
②Resolution: 1%
③Accuracy: 70% ~ 100% (2 %)
④Pulse Rate: 20-250 BPM
⑤Resolution: 1 BPM
⑥Accuracy: 3 BPM
2.NIBP
2.1.Method: Oscillometry
2.2.Measure mode: Manual, Auto, STAT
2.3.Unit: mmHg, kPa
2.4.Measure and alarm range:
2.5.Adult Mode
①SYS 40 ~ 280 mmHg
②DIA 10 ~ 225 mmHg
③MEAN 20 ~ 240 mmHg
2.6.Pediatric Mode
①SYS 40 ~ 220 mmHg
②DIA 10 ~ 160 mmHg
③MEAN 20 ~ 170 mmHg
2.7.Neonatal Mode
①SYS 40 ~ 135 mmHg
②DIA 10 ~ 100 mmHg
③MEAN 20 ~ 110 mmHg
2.8.Resolution: 1mmHg
2.9.Accuracy: 5mmHg
3.TEMP
①Measure and Alarm Range: 0 ~ 50 C
②Resolution: 0.1C
③Accuracy: 0.1C
Standard Configuration:
1.Main Unit *1
2.Adult Spo2 probe *1
3.Adult NIBP cuff *1
4.NIBP extension tube *1
5.Power Cable *1
6.Power adapter *1
7.User Manual *1
8.Temperature probe *1
/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
PM80D
Features:
1.Unique accessory management cabinet
2.8 inch high resolution color TFT display
3.USB interfaces support easy software upgrade and data transfer
4.Three Working Modes: Monitoring, Surgery and Diagnosis.
5.Simple and friendly operating display interface.
6.Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
7.Built-in high capacity battery up to 3 hours of continuous work
Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR
Technique Specification:
ECG
1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4.ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6.Bandwidth:
7.Diagnostic: 0.05~130 Hz
8.Monitor: 0.5~40 Hz
9.Surgery: 1~20 Hz
SPO2
1.Measuring Range: 0 ~ 100 %
2.Resolution: 1%
3.Accuracy: 70% ~ 100% (±2 %)
4.Pulse Rate: 20-250 BPM
5.Resolution: 1 BPM
6.Accuracy: 3 BPM
NIBP
1.Method: Oscillometry
2.Measure mode: Manual, Auto, STAT
3.Unit: mmHg, kPa
4.Measure and alarm range:
5.1 Adult Mode
① SYS 40 ~ 280 mmHg
② DIA 10 ~ 225 mmHg
③ MEAN 20 ~ 240 mmHg
5.2 Pediatric Mode
① SYS 40 ~ 220 mmHg
② DIA 10 ~ 160 mmHg
③ MEAN 20 ~ 170 mmHg
5.3 Neonatal Mode
① SYS 40 ~ 135 mmHg
② DIA 10 ~ 100 mmHg
③ MEAN 20 ~ 110 mmHg
6.Resolution: 1mmHg
7.Accuracy: 5mmHg
RESP
1.Method: Impedance between RA-LL or RALA
2.Measurement Range:
① Adult: 10 ~ 120 BrPM
② Neonatal / Pediatric: 7 ~ 150 BrPM
3.Resolution: 1 BrPM
4.Accuracy: 2 BrPM
TEMP
1.Measure and Alarm Range: 0 ~ 50℃
2.Resolution: 0.1℃
3.Accuracy: 0.1℃
Standard Configuration:
Main Unit *1
5-lead ECG cable *1
Disposable ECG Electrode *5
Adult Spo2 probe *1
Adult NIBP cuff *1
NIBP extension tube *1
Temperature probe *1
Power Cable *1
User Manual *1
FDA Statement:
The sale of this item may be subject to regulation by the U.S. Food
and Drug Administration and state and local regulatory agencies.
So you can bid it on this item only if you are an authorized purchaser.
If the item is subject to FDA regulation,We have to verify your status
as an authorized purchaser of this item before shipping of the item.
Thanks for your understanding!