portable multi-gas detector could detect combustible gas, O2 and other two types toxic gases continuously and simultaneously. It is widely used in the area where explosion-proof is required or toxic gas leaks, like underground channels or mining industry, so as to protect the workers’life and avoid damage on the relevant equipments.
INTRODUCTION
* Natural diffusion sampling method and high-sensitivity sensor, with high sensitivity and repeatability.
* 32-bit built-in MCU, high reliability and self-adaptation ability.
* Full functions, easy operation.
* CSTN colorful LCD, more intuitionistic, abundant and clear indication.
* Compact design, easy carrying.
* High strength engineering plastics and compound anti-slippery rubber; high strength, water-proof, dust-proof and explosion-proof.
*500pcs data records, can be contact with computer via software. Can print the data records, can store data records, can make the data analysis.
Specification:
| Gas sampling method |
Natural diffusion |
| Detecting gas |
Combustible gas, H2S, CO, O2 |
| Accuracy |
≦±5% F.S. |
| Response Time |
≦30s |
| Indication |
LCD displays real-time and system status; LED, audio and vibration alert for gas leakage, fault and low voltage. |
| Working environment |
-20℃~50℃ for toxic gases -40℃~70℃ for Ex <95%RH (no dew) |
| Power Source |
DC3.7V Li-on battery, 1800mAh |
| Charging time |
6h~8h |
| Working time |
≧8h continuously (without alarming) |
| Gas Sensor Life |
2 years |
| Explosion-proof grade |
Ex ib IIB T3 Gb |
| Protection Grade |
IP65 |
| Weight |
Appr. 400g (with battery) |
| Dimensions |
130mm×67mm×30mm(L × W × H) |
SPECIFICATIONS
| Range |
Resolution |
L-alarm |
H-alarm |
|
| CO |
0-1000ppm |
1ppm |
50ppm |
150ppm |
| O2 |
0-30%vol |
0.1%vol |
19.5%vol |
23.5%vol |
| H2S |
0-100ppm |
0.1ppm |
10ppm |
20ppm |
| EX |
0-100%LEL |
1%lel/1%vol |
20%LEL |
50%LEL |