3 Phase Power Quality Analyzer Power Energy Meter with 4PCS Round Current Sensor

This Power Quality Analyzer comes with 4PCS DZF-3Q-100AClamp Sensors, 0.10A~100A Range.

If you needs other sensors, please contact us.

Introduction:

Product Main Function:

General Specification:

Power supply

Rechargeable lithium-ion battery packs 9.6V, backup charger.

Battery Level indicator

Battery symbol 5 grid Display power, when the battery level is low, automatically shut down after 1 minute indication

Working Current

about 590mA, continuous working 8hours.

Display mode

LCD color screen, 640dots × 480dots, 5.6 inches, display field 116mm × 88mm

Instrument Size

240mm×170mm×68 mm.

CT Size

DZF-3Q-100A round jaw current clamp: 35mm×40mm;

Number of channels

4 voltages, 4 currents

Line Voltage

1.0V~2000V.

Phase Voltage

1.0V~1000V.

Current

DZF-3Q-100A current clamp: 0.10A~100A;

Frequency

40Hz~70Hz.

Electricity Energy Parameter

W, VA, Var, PF, DPF, cosφ, tanφ.

Energy parameters

Wh, Varh, Vah.

Harmonic Wave

Yes, 0 - 50 times

Total harmonic distortion

Yes, 0 - 50 times, each phase

Expert Mode

Yes.

Transient Record Groups

150 groups

Voltage Flicker

Yes

Start Current Mode

Yes, 100 seconds

Three-phases Unbalance

Yes

Record

300 days (record 20 parameters simultaneously, every 5 seconds record 1 point)

Min/Max Recorded Value

Yes, the max min value can be measured for a certain time

Alarm

40 different types of parameter selection, 12800 group alarm logs

Peak

Yes.

Phasor Diagram Display

Automatic

Screenshot Capacity

60PCS

Menu language

English/Chinese.

Communication Interface

USB.

Automatic Shut Down

In the alarm/trend graph recording/transient capture mode (waiting or in progress), the instrument does not automatically shut down

In other test modes, there is no button operation within 15 minutes, prompting to automatically shut down after 1 minute.

Backlight Function

Yes, suitable for dark places and nighttime use

Instrument Weight

Host: 1.6kg (with battery).

DZF-3Q-100A circle current clamp: 190g×4;

Test wires and power adapter: 900g;

Total weight: about 9.2kg (with package).

Voltage Test Wire Length

3M

Current Clamp Wire Length

2M

Working Temperature

-10°C~40°C; below 80%Rh.

Storage Temperature

-10°C~60°C; below 70%Rh.

Input Impedance

Test voltage input impedance: 1MΩ

Withstand voltage

Withstand the sine wave AC voltage of 3700V/50Hz one minute between the instrument line and out shell

Insulation

Between instrument line and shell ≥10MΩ.

Structure

Double insulation, with insulation shock-proof sheath.

SuitableSafely Standard

IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.

Accessories

Host: 1PCS; Instrument Bag: 1pcs; Test Cable: 5PCS (yellow, green, red, blue, black); Alligator Clip: 5PCS; Probe: 5PCS; Charger 1PCS; Software CD: 1COPY; 2G Memory Card: 1PCS;Current Clamp DZF-3Q-100A 4PCS


The following data are presented in reference conditions and ideal current sensors Instrument Accuracy  (excluding the current sensor)

(completely linear and without phase displacement).

Measurement Specification

Range

Display Resolution

Max Error of Reference Range

Frequency

40Hz70Hz

0.01Hz

±(0.03)Hz

Phase Voltage True RMS

1.0V1000V

Min resolution0.1V

±(0.5%+5dgt)

Line Voltage True RMS

1.0V2000V

Min resolution0.1V

±(0.5%+5dgt)

DC Voltage

1.0V1000V

Min resolution0.1V

±(1.0%+5dgt)

Current True RMS

10mA3000A

Min resolution0.1mA

±(0.5%+2dgt)

Phase Voltage Peak

1.0V1414V

Min resolution0.1V

±(1.0%+5dgt)

Line Voltage Peak

1.0V2828V

Min resolution0.1V

±(1.0%+5dgt)

Current Peak

10mA4200A

Min resolution0.1mA

±(1.0%+5dgt)

Peak Factor

1.003.99

0.01

±(1%+2dgt)

4.009.99

0.01

±(5%+2dgt)

Active Power

0.000W9999.9kW

Min resolution0.001W

±(1%+3dgt);Cosφ≥0.8

±(1.5%+10dgt);0.2≤Cosφ<0.8

Reactive power

Inductive& Capacitive

0.000VAR9999.9kVAR

Min resolution0.001VAR

±(1%+3dgt);Sinφ≥0.5

±(1.5%+10dgt);0.2≤Sinφ<0.5

Apparent Power

0.000VA9999.9kVA

Min resolution0.001VA

± (1%+3dgt %)

Power Factor

-1.0001.000

0.001

±(1.5%+3dgt);Cosφ≥0.5

±(1.5%+10dgt);0.2≤Cosφ<0.5

Active Energy

0.000Wh9999.9MWh

Min resolution0.001Wh

±(1%+3dgt);Cosφ≥0.8

±(1.5%+10dgt);0.2≤Cosφ<0.8

Reactive Energy

Inductive& Capacitive

0.000VARh9999.9MVARh

Min resolution0.001VARh

±(1%+3dgt);Sinφ≥0.5

±(1.5%+10dgt);0.2≤Sinφ<0.5

Apparent Energy

0.000VAh9999.9MVAh

Min resolution0.001VAh

±(1%+3dgt)

Phase Angle

-179°180°

±(2°)

Tanφ(VA≥50VA)

-32.76832.768

Min resolution0.001

±(1%+5dgt)

Displacement Power Factor(DPF)

-1.0001.000

0.001

±(1%+5dgt)

HarmonicRatio(Vrms>50V)

0.0 %99.9 %

0.1 %

±(1%+5dgt)

Harmonic Angle(Vrms >50V)

-179°180°

±(3°)harmonic1~25

±(10°)harmonic26~50

Total Harmonic Rate

(DF or THD-F)≤50

0.0 %99.9 %

0.1 %

±(1%+5dgt)

Distortion Factor

(DF or THD-R)≤50

0.0 %99.9 %

0.1 %

±(1%+10dgt)

Transformer K Factor

1.0099.99

0.01

±(5 %)

Three-phase Unbalance

0.0%100 %

0.1 %

±(1 %)