TWO Sylvania SX 245 tubes

Tubes test 1600 and 1750 where pass/fail is 1100 micromhos

245 globe balloon shape

Top green leaf excellent condition

Round cup getter

Double Triangle mica support

Hot stamp / etched / engraved base

No shorts / no gas

Tight base

Test results=

Tube #1 = 1600 micromhos @ 24.2 mA plate current

Tube #2 = 1750 micromhos @ 24.6 mA plate current

For reference:

Tubes Tested on Westmore 501 tube tester where 2200 micromhos and 34mA plate current are bogey values

1100 micromhos snd 22.1 mA is reject (pass/fail) value

USA = usps priority

International = UPS or global post office shipping