The KZYEE KM05 kit is the most revolutionary circuit tester to date, which works off of 12-24 Volt sources, featuring DC Voltage, AC Voltage,  Resistance, and Diode, Activate and Test the Electronic Component , users can long-press the mode button to switch between Waveform Display Mode and Digital Display Mode. Theis indeed the ultimate in power and affordability, allowing users to check circuitry in one single step. An absolute must for every technician who is looking for a fast and accurate solution to electrical systems diagnostic.

TIPS:

1.KM05 is ONLY for 12-24V vehicle battery electrical systems, and should NOT be used to test 110/220V household electric appliances; or, it will be damaged.

2. The LED and LCD pull no more than 100 milliamps of current, therefore when using this device as a test light or multimeter, it is safe for computers and airbags.

3.When powering-up components, you can increase the life of rocker switch in the tool if you first press the switch, and then contact the tip to the component. The arcing will take place at the tip instead of the metal contacts of the rocker switch.


Product function introduction
1) DC voltage test function, up to 60V
2) AC test function, can capture AC maximum and minimum values, test range 0~60V, and at the same time can display the AC signal waveform, frequency.
(3) Resistance test function, test range 0 ~ 100KΩ, when the test resistance is less than 100Ω buzzer alarm.
(4) Diode test function, can detect the diode forward voltage, in the diode function long press the up key can realize the mute function.
5) Import positive or negative battery current to the tip, used to activate and test the electronic component function. (Equivalent to adding a fuse wire)
6) This product also features illumination, sharp detection tip, long enough power cord and extension cord, cigarette lighter connector and clip. 
 
Product Specifications
DC voltage :0~60V   
AC Voltage : 0~60V /0~10KHz
Resistance: 0~100KΩ
Diode: 0~3V
Positive or negative current: 8A

 

Instrument Introduction
① Probe - Contacts the circuit or component under test.
② Front light - Illuminates dark work area or at night.
③ Red/Green Polarity Indicator - Identifies positive, negative, or open circuit. The red indicator lights when the probe contacts a positive circuit. When the probe contacts a negative circuit, the green indicator light is on.
④ LCD Display - Displays test results.
⑤ Power Switch - Allows you to draw positive or negative battery current to the tip to activate and test electronic component functions.
⑥ Mode Button - Selects the mode of operation: AC Voltage, DC Voltage, Resistance, Diode.
⑦ Auxiliary Ground Wire - Serves as an auxiliary ground wire for testing.
⑧ Battery Clamp Cable - Connects to the battery.
Fuel Injection:Voltage: 0~180V, Time: 0~25ms
 

 

Features:

DC Voltage Mode

DC mode is for testing DC (direct current) voltages. Voltage testing is as easy as contacting the probe tip to a circuit and reading the display. DC Mode is the mode that the KM05 can supply battery power or ground by pressing the rocker switch.

AC Voltage Mode

The auxiliary ground wire is connected to one end of the circuit under test, and the probe contacts the other end of the test circuit. The LCD will display the max and mini voltage value, and display the signal waveform in real-time. You can adjust the sampling frequency by pressing the Up/Down Button.

Resistance Testing Mode

The probe contacts one end of the measured resistance, and the auxiliary ground lead is connected to the other end of the measured resistance. The LCD will display the resistance between the tip and auxiliary ground lead. When resistance value is less than 30Ω, the instrument buzzer will alarm and the green LED will light. This function can be used as continuity test.

Diode Testing Mode

Contact the probe tip to diode positive terminal, connect the auxiliary ground lead to the diode negative terminal, the screen will display the forward voltage drop, which indicates forward bias. If swapping the probe tip with auxiliary ground lead, the screen will not display voltage, which indicates reverse bias. It also displays the max and mini values during measurement.

Manual Activation Component

 

For example, to activate a light bulbproceed as follows:

1.Press the power switch forward to activate the light bulb.

2.Touch the probe to the positive terminalof the light bulb.

3.Connect the negative auxiliary clamp


On Sep 12, 2026 at 14:01:06 AEST, seller added the following information: