Apator PoWoGaz MWN-125-NK (HV) water counter with pulse exit turbine 65,14.








Turbine Powogaz MWN-125 cold water meter is designed to measure the flow of large volumes of cold water up to 30 ° C or 50 ° C, with a maximum working pressure of 16 bar (PN 16). It is built in horizontal pipelines with a meter pointing up (H), vertical or horizontal with a meter pointing in the direction (V) or at an angle (H / V). The MWN meters in the standard model are equipped with a 6-chamber drum counter (IP65, IP68 optional) and a painted metal housing. Counters are provided for work in systems of remote data transmission (AMR).


Metrological class:


Cold water R630 ÷ R4000 - H


Product features:

- Preequipped for installation of: radio module for communication in the Wireless M-Bus, M-Bus module and impulse module (not applicable to water meters for hot water and versions with NK, NO, NKO and NKOP transmitters)

- Wide measuring range

- Low starting rate

- Removable measuring panel

- Double-sided rotor bearing

- Easy reading of the water meter counter

- Hermetic counter - IP68 on request (cold water only, pre equipped for radio transmitters - Wireless M-Bus standard or NK transmitter with pulse range 10, 100, 1000 dm3/imp. (not applicable to NO and NKO))

- Counter mechanism with blockade against multiple rotating, at rotation angle more than 360°

- Readings reliability

- In special option housing with connection for pressure measurement DN50-300 (cold and hot water)

- Optional version for demineralised water DN40-125 (cold and hot water)

- On request possibility of another drilling



PRODUCT CHARACTERISTICS


Used for mounting wireless radio in the standard Wireless M-Bus and pulse lining (does not apply to models with transmitting devices NK)Wide measuring rangeLow trigger thresholdRemovable measuring insertRotor with double-sided bearingEasy meter readingSealed counter - IP68 on request *Locking rotation of the counting mechanism, when rotating at an angle of more than 360 °Accuracy of indicator


Specifications


Conditional pass (DN or Dn) 125 mm

Construction length 250 mm

Joining flange

Nominal flow, Qn250 cubic meters / h

Pulse output not

Purpose for cold water

Counter type mechanical (tachometer)

Installation position horizontal, vertical, inclined

Modification industrial

Body material cast iron

Equipment without fittings

Maximum working pressure 16 bar

Maximum temperature + 50 ° C

Counter brand Powogaz MWN

Intertesting interval 4 years

Price division of the counting device 0.0005 l

Maximum meter reading 999999 cubic meters

Metrological class AT





Specifications

Meter type mechanical

Application area industrial

Use for cold water

Flange connection

Nominal diameter DN (DN) 125 mm

Thread diameter in inches 5 "

Nominal flow rate Qn 250 cubic meters / hour

Installation length 250 mm

Maximum temperature of the measured medium 50 ° С

Maximum working pressure 16 bar

Body material cast iron

Pulse output yes

Design feature turbine, anti-magnetic shielding, dry-running

Installation method vertical, horizontal, inclined

Metrological class B

Calibration interval 4 years

Powogaz MWN Marking

Manufacturer Apator Powogaz

Country of origin Poland

Complete set without fittings



Rf/13b