Preferences |
Single Door/Bidirectional Controller |
2-Door/Bidirectional Controller |
4-Door/Unidirectional Controller |
|
Model |
WG2001 |
WG2001.NET (this is it)
|
WG2002 |
WG2002.NET
|
WG2004 |
WG2004.NET |
|
Software Download |

|
|
Communications |
RS485 |
TCP/IP 10M/100M Self-adaptive |
RS485 |
TCP/IP 10M/100MSelf-adaptive |
RS485 |
TCP/IP 10M/100MSelf-adaptive |
|
Description |
One door,Card enter,Card or button exit |
2 doors,Card enter,Card or button exit |
4 doors,Card enter,Button exit |
|
PCB Dimensions |
160mm *106mm |
160mm *106mm |
218mm*106mm |
|
Iron Box Dim |
273mm*228mm*65mm |
|
Power Supplier |
12VDC 4-7A |
|
Current |
<100mA |
|
Acceptable Card Readers' Format |
Wiegand 26bit or 34bit(optional by hardware switch,default is 26bit) |
|
Extensible Card Readers |
2 |
4 |
4 |
|
Door(s) for control |
1 |
2 |
4 |
|
Delay |
1-600 seconds adjustable |
|
Max units online |
N*256 |
Unlimited |
N*256 |
Unlimited |
N*256 |
Unlimited |
|
|
Note:"N" means quantity of Com ports or RS485 Hub's ports |
|
Working Temperature |
-40 ~70 Centigrade |
|
Working Moisture |
10-90%RH |
|
Max Users Quantity |
20,000 |
|
Event records quantity |
100,000 |
|
Power off Protection |
High speed flash memory,keep data safe without power |
|
Max Distance from Reader to Controller |
Max to 100M |
|
Max Distance from Controller to PC |
RS485:Max to 1,200M,Reliable value 1,000M,can be extended up to 3000 M by RS485 relay. |
|
TCP/IP:According to the network coverage |
|
Accessories |
PCB*1pcs,CD*1pcs,Manual*1pcs,Certificate*1pcs,Carton * 1pcs |
|
Alarm when:Door un-closed overtime,unlawful entry or being Threatened |
yes |
yes |
yes |
|
Fire protection &Alarm Trigger |
If
theft or fire occurs,the software can alarm by PC's speaker.If the
controller contact to "alarm external module",it can also drive the
alarm Siren, |
|
Hold the door open/closed by software |
yes |
yes |
yes |
|
Remote open by software |
yes |
yes |
yes |
|
Programmable Interrelation of doors' condition(open/closed) |
|
yes |
yes |
|
Note:you
can setup the interrelation between the doors Arbitrarily,such as "only
when door A is open &door B is closed,Door C can be openned" |
|
Anti go back convertly,Anti followed |
yes |
yes |
|
|
Note:This function means if a card has already exited,it can not exit again without enter. |
|
Multi-card open |
yes |
yes |
yes |
|
Note:A
door can be openned only when 2 or more cards are read(multiple persons
are present). This function maybe useful for very important place. |
|
programmable time of hold open |
yes |
yes |
yes |
|
Note:can setup the door hold open at a specified time,maybe useful during the period of going to work every morning |
|
Electrical Map |
yes |
yes |
yes |
|
Note:Can easily know your doors' condition vividly from the software. |
|
Urgently close Both enter&exit |
yes |
yes |
yes |
|
Note:The door(s) can be hold closed,refuses both enter and exit in case of theft or other accident occurs. |
|
Initial Card |
yes |
yes |
yes |
|
Note:If Initial Cards was activated,Only after Initial card is read,Other user cards can be available. |
|
validate from both side |
yes |
yes |
yes |
|
Note:Door can be set to openned only when card reading from both outside and inside of the door. |
|
Extensible pin code RFID reader(card+pin code/super password) |
yes |
yes |
yes |
|
Note:Door can be set to openned only when both card reading and pin code pressed. |