Range: 0-4KPA~40MPA
Pressure type: gauge pressure, absolute pressure, negative pressure
Overload capacity: allowable overload: 1.5 times the sensor range
Destruction pressure: 2 times the sensor range
Zero temperature drift: 0.03%FS/C (≤100KPA); 0.02%FS/C (>100KPA)
Full-scale temperature drift: 0.03%FS/PC (≤100KPA); 0.02%FS/C (>100KPA)
Accuracy grade: 0.1%, 0.25%, 0.5%
Long-term stability: 0.2%/year
Allowable temperature: normal working temperature -20℃~70℃
Power supply: (10~30) VDC, 24VDC is recommended
Output signal: 4~20MADC, 1-5VDC three-wire system, RS485 output load: 50 (U-12) Q
Insulation resistance: >100MQ@50V