Underground Utilities Locator Kit Real-time Display Cable Depth Current Value
Intelligent pipeline detector, also known as underground utility cable locator, cable path instrument, is a path detection instrument with strong comprehensive performance. It has pipeline path detection, cable identification, fault search and other functions. The instrument is composed of transmitter, transmitting current clamp, receiver, receiving flexible current clamp, connecting test line, A-fault locator frame (optional), etc.Intelligent pipeline detector can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables under trenchless excavation. The instrument uses a variety of filtering technologies, has anti-interference ability, and can accurately locate and depth. It is suitable for the detection and patrol of underground metal pipelines, pipeline management and maintenance, municipal planning and construction, power supply and other departments, etc. It is one of the necessary instruments of pipeline maintenance units。
This function is realized by the signal transmitter, the receiver, the signal transmitting clamp and the connection test line. The instrument has the following characteristics:
1. Multiple detection modes: classic positioning mode, wire cruise mode, peak and trough mode;
2. Classic positioning mode: compass, direction and signal amplitude display, visually display the left and right direction of the pipeline。
3. Lead cruise mode: 360 omnidirectional pipeline path indication, continuous display of depth, current, and pipeline relative position. The interface is simple and intuitive, and it can be operated without experience
4. Peak trough mode: display the peak trough waveform at the same time, and can analyze whether the underground pipeline has parallel line signal interference through the waveform, so as to prevent the measurement error caused by the interference.
5. Current direction determination (partial frequency), can be calibration current direction, eliminate adjacent line interference, to prevent tracking errors.
6. Full digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow reception frequency band, strong anti-interference ability, can fully inhibit the power frequency and harmonic interference of adjacent running cables and pipelines.
7. Multiple detection frequencies: 13 active detection frequencies and 2 passive detection frequencies.
8. Multiple signal output modes: direct connection output, caliper coupling, induction method.
9. Transmitter digital amplifier power output, automatic impedance matching, automatic protection.
Cable identification is designed for power cable engineers and cable workers to solve the technical problems of cable identification. Can be used to identify live cables and blackout cables. The user accurately identifies one of the target cables from multiple cables through the instrument to avoid missawing non target cables. When cable identification, 20 cables can be pre-rated at the transmitting end, and then received and identified at the far end, which greatly saves the calibration operation time of engineering personnel and improves the work efficiency. Cable identification success hit, non-target cable hit, can quickly and automatically identify the target cable. This function is realized by the signal transmitter, receiver, signal transmitting clamp, connecting test line and flexible caliper.
Signal transmitter: used for pipeline path detection and cable identification.The device can add identification signals to the target cable through direct connection output, caliper coupling, induction method, and so on. There are 13 different pulse signals of 250Hz, 577Hz, 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 33 kHz, 66 kHz, 82 kHz, and 197 kHz.The maximum signal output power is 15W, and 6 levels are adjustable, adapting to different application environments, making pipeline detection and cable identification more accurate and reliable.Instrument built-in large function rate can be charged with lithium battery, automatic impedance matching, automatic protection.The transmitter adopts the integrated special toolbox design, its box can withstand the pressure of about 200kg, the host 5 inch capacitor touch LCD display, real-time dynamic display signal output status and battery usage.
Transmitter Clamp:Suitable to caliper coupling method.The transmitting clamp couples the signal from the transmitter to the target cable, the jaw size is Φ125mm, the transmitting clamp is directional, and the emission signal flows from the direction indicated by the arrow on the transmitting clamp.
Receiver:For pipeline path detection and cable identification. Built-in shielding 3D antennas can effectively identify 13 different pulse-coded current signals of 250Hz, 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 33 kHz, 66 kHz, 82 kHz and 197 kHz generated by the transmitter, and 50Hz and 60Hz power frequency signals and center frequencies of 33 kHz and 82 kHz.Use a 4.3-inch capacitive touch LCD screen, real-time dynamic display of 360 comprehensive pipeline path indication, depth, current and relative pipeline position.
Flexible current clamp:For the cable identification. The current clamp is a Roche coil, with excellent transient tracking ability, and can quickly identify the pulse width frequency signals generated by the transmitter. It is suitable for thick cables or irregularly shaped conductors.The inner diameter of the jaw is about 200mm, can clamp Φ200mm below the cable, do not need to disconnect the measured line, non-contact measurement, safe and fast.
Special note: When power outage cable identification: no access to the live cable. Live cable identification is only applicable to three-core armored cable. When identifying, the transmitting clamp and the receiving clamp should not be mixed, and the direction of the input signal should be consistent.
Technical parameters:
Receiver specifications
Function | Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A word frame fault search (optional function) |
Power | 8.4V large capacity rechargeable lithium battery |
Input mode | Built-in receiver coil, flexible caliper, A-character frame (optional function) |
Receive frequency | Active detection frequency:250Hz、577Hz、640Hz、1.28kHz、2.56kHz、3.20kHz、4.09kHz、8.19kHz、10.2kHz、33kHz、66kHz、82kHz、197kHz Power frequency passive detection frequency:50Hz、60Hz RF passive detection frequency band: the central frequency is divided into33kHz、66kHz、82kHz、197kHz |
Pipeline detection mode | Wide peak method, narrow peak method, sound valley method |
Pipeline detection display | Classic positioning mode, wire cruise mode, peak and trough mode |
Pipeline detection Range of detection | Direct connection method: generally can reach the cable length of 0~20 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth Coupling method: generally can reach the length of the cable 0~10 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth Induction method: suitable for cables with buried depth less than 2m |
Depth and current | Display the cable depth and current value in real time |
Pipeline measurement depth | 0-20m |
Deep precision | Plane position precision accuracy: the central axis position of the target cable or line: ±5%(Buried deep in0-3m)-10%(Buried deep in3m-20m) |
Positive and wrong prompt | Excluding the interference of adjacent cables, in the measurement of adjacent cables, the measurement of the adjacent cables can be distinguished according to the different signal strength and the measured current phase of the adjacent cables. In the process of tracking the cables, the phase dial and pointer can be observed to distinguish the measured cables and the adjacent cables |
Sound instructions | FM tone with signal intensity |
capacity of resisting disturbance | Very narrow receiving frequency band and unique digital processing method can fully suppress the power frequency and harmonic interference of adjacent operating cables and pipelines |
interference distance | When using the coupling method and the induction method, the transmitter will produce interference in close distance. The distance of interference is related to the transmission power and frequency. The greater the power, the higher the frequency, the stronger the interference. The minimum distance of the receiver without disturbed by the transmitter often needs to be determined by test: Pipeline detection: 5m away, 20m away as no interference Cable identification: the coupling method beyond 2~5m can be confirmed as no interference |
Cable identification | Identification mode: flexible caliper intelligent identification; Number of calibrate cables: 1~20; Calibration value: the current percentage of the received signal and the transmitted signal between 75% and 135% of the calibration value is one of the conditions for successful identification; Directionality: the transmitter clamp, receiver clamp must be in the same direction as the loading signal, which is one of the conditions for successful identification |
Cable identification Range of detection | Direct connection method: can identify the signal with a circuit resistance of 0 Ω ~ 8 kΩ (generally, the length of the cable can reach 0~20 km, mainly determined by the grounding resistance and cable resistance) Coupling method: can identify the signal with circuit resistance of 0 Ω ~ 1 kΩ; (generally the cable length is 0~6 km, mainly determined by the grounding resistance and cable resistance) |
Display | 4.3 LCD color screen LCD (highlight screen), visible in the sun |
Touch screen | Yes |
Size | 350mm(length)×155mm(width)×700mm(high) |
Weight | 2kg |
Connection interface | Type-C USB interface, air socket |
Coil inner diameter | φ200mm(A larger caliber can be customized as needed) |
Working temperature and humidity | -10℃~40℃;Below 80%Rh |
Store temperature and humidity | -10℃~50℃;≤95%RH, No condensation |
withstand voltage | AC2000V/rms(Before the front and rear ends of the enclosure) |
Suitable for safety regulations | IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,Pollution grade 2 |
Transmitter specifications
Function | Multiple frequency signal transmission modes |
Power | 10.8VLarge-capacity rechargeable lithium battery |
Output method | Direct connection method, caliper coupling method, induction method |
Output mode | Automatic identification, according to different accessories |
output frequency | 250Hz、577Hz,640Hz,1.28kHz,2.56kHz,3.20kHz,4.09kHz,8.19kHz,10.2kHz,33kHz,66kHz,82kHz,197kHz |
Output power | 15 Wmax, 6-gear adjustable |
impedance | Automatic real-time impedance matching and protection function |
Direct output voltage | 150Vpp max |
Circuit protection | With overload and short-circuit protection |
Display | 5-inch LCD color screen |
Touch screen | Yes |
Instrument size | 320mm(Length)×275mm(Width)×145mm(High) |
Weight | The transmitter is about 3.85kg; the transmitter clamp is about 1.18kg |
Transmitter clamp inner diameter | φ125mm |
cable length of transmitter clamp | 3m |
Test cable | Red test cable 3m, black test cable 3m |
Connection interface | USB interface, DC interface, aviation socket |
Resistance to pressure | The transmitter adopts an integrated special tool box type design, and the box body can withstand the pressure of about 200kg |
Withstand voltage | AC 3700V/rms(Before the top surface and bottom surface of the instrument box) |
Electromagnetic characteristics | IEC61326(EMC) |
Suitable for safety regulations | IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、class of pollution 2) |
◆Note: This introduction is for reference only. Please read the instruction manual for detailed parameters.
Packing list:
Transmitter | 1pcs |
Receiver | 1pcs |
Tool cloth bag | 1pcs |
Coupling transmitter clamp | 1set |
Receive the flexible current clamp | 1set |
Crocodile clip test cable | 1pcs |
Two-headed alligator clip test cable | 1pcs |
Ground needle | 1pcs |
Receiver charger | 1pcs |
Transmitter charger | 1pcs |
USB data wire | 2pcs |
Instructions, warranty card, qualification certificate | 1set |