| Specification | |
|---|---|
| Maximum capacity ( Emax ) | 0.5/1/2/2.5/3/4/5/6/7.5t 1/1.5/2/2.5/3/4/5/7.5/10/20 klb |
| Accuracy class | C3 |
| Maximum number of load cell intervals ( nLC ) | 3000 |
| Ratio of minimum LC verification interval Y = Emax / vmin | 10000 |
| Combined error %FS | ±0.020 |
| Creep %FS/30min | ±0.016 |
| Temperature effect on sensitivity %FS/10℃ | ±0.011 |
| Temperature effect on zero %FS/10℃ | ±0.015 |
| Output sensitivity ( = FS ) mV/V | 3.0±0.003 |
| Input resistance Ω | 350±3.5 |
| Output resistance Ω | 350±3.5 |
| Insulation resistance MΩ | ≥ 5000(50VDC) |
| Zero balance %FS | ±1.0 |
| Compensated temperature ℃ | -10 ~ +40 |
| Operating temperature ℃ | 35 ~ +70 |
| Excitation, recommended voltage V | 5 ~ 12(DC) |
| Excitation maximum V | 18(DC) |
| Safe overload %FS | 150 |
| Ultimate overload %FS | 300 |
| Recommended torque on fixation N.m | M12: 100, M18: 200, M24: 700 |
| Ingress protection (according to EN 60529) | IP67 |