New 30W Din Rail Mounted 12VDC 2A Output Power supply
SPECIFICATIONS
INPUT
Voltage Range 85~264 VAC47~63 Hz; selected by switch 120~370VDC
AC Current 0.88 A/115 V 0.48A/ 230 V
Efficiency 74%(HDR-30-5); 81%(HDR-30-12); 82%(HDR-30-15); 83%(HDR-30-24)
Inrush Current Cold start 15A/115V 30A/230V
PROTECTION
Over Load 105%~160%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 115%~135%
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT
Working Temp., Humidity -10℃~+60℃;20%~90 %RH
Storage Temp., Humidity -20℃~+85℃;10%~95 %RH
Vibration 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage I/P-O/P: 3KVAC
Isolation Resistance I/P-O/P: 100M Ohms / 500VDC
STANDARD
Safety Standard Design refer to UL60950-1,TUV EN60950-1,EN50178
EMC Standard Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3
OTHERS
Weight 0.27Kg
Packing 48pcs/14Kg/1.02CUFT
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OUTPUT
Model DR-30-5 DR-30-12 DR-30-15 DR-30-24
DC Voltage 5V 12V 15V 24V
Voltage Tolerance ±2% ±1% ±1% ±1%
Rated Current 3A 2A 2A 1.5A
Current Range 0-3A 0-2A 0-2A 0-1.5A
Rated Power 15W 24W 30W 36W
Ripple & Noise 80mVp-p 120mVp-p 120mVp-p 150mVp-p
DC Adjustment Range -5%,+10% ±10% ±10% ±10%
Setup, Rise, Hold Time 100ms,30ms/230VAC100ms,30ms/115VAC at full load