This item located in Germany and only ship to some European Countries.
If you need to return the item for some reasons, pls contact us via ebay message at the fist time, we will try our best to help you and arrange the return for you. Pls do not send back directly without permission.Thank you!!!
LAUNCH X431 O2-2 Oscilloscope Scopebox Analizador 4 Channel Digital Scopebox Tester USB Port Works with X431 PAD VII, PAD V, PAD III One key enable function Access to 23 variants of automatic measurements that are displayed on one screen for an easy switch. Buffer memory up to 50M. Use the zoom in/out feature to review precise details Customizable personal system settings that can be saved as configuration files for viewing Self-calibration function allows optimization of the oscilloscope signal path for maximum measurement accuracy. Magnifies waveform math operations, such as addition, subtraction, multiplication and FFT function for high level waveform analysis. Multiple automotive tests that include circuits, sensors, actuators, ignition tests and more. Multi-language user interface. USB Sync Data Transfer to external devices such as laptop, tablet, etc.... Model O2-1 O2-2 Channel 4 4 Bandwith 100MHz 100MHz Rise Time â€3.5ns(typical) â€3.5ns Maximum sampling rate 1Gbps(for four channels) 1Gbps Input resistance 1MΩ±1.5% 1MΩ±1.5% Storage depth 50M 10M Number of sampling bits 8bit 8bit vertical accuracy 3% 3% Vertical gear 5mV~10V 5mV~10V Inverting Support Support Channel coupled DC, AC DC, AC Time base gear 5ns~1ks 1ns-1ks Time base accuracy 20ppm 20ppm Sampling mode Normal Normal CANBus decoding CAN, LIN CAN, LIN Trigger type Edge, Pulse width Edge, Pulse width Trigger mode Normal, Auto and Single SEQ Normal, Auto and Single SEQ Trigger coupling DC, Noise rejection DC, Noise rejection Math Double wave\FFT Double wave\FFT Display YTăZoomăRoll YTăZoomăRoll Roll mode 200ms/div~1000s/div 200ms/div~1000s/div Auto configuration Support Support Auto measurement 23 23 Cursor Horizontal cursor, Vertical cursor Horizontal cursor, Vertical cursor Powered by USB port, DC IN port USB port, DC IN port Data transmission method USB USB Vehicle configuration options Circuits, sensor, actuators, ignition Circuits, sensor, actuators, ignition Operating temperature 0â~50â 0â~50â Power supply range USB:5V/1A USB:5V/1A Compatibility Different tablet resolutions require different APPs One APP can be compatible with multiple tablet resolutions Multi-touch gestures No Supports 2-point touch, the waveform can be zoomed in or out vertically or horizontally Vehicle configuration No Each test project can support online help documentation (help documentation will be compiled according to needs later) Firmware upgrade Manual upgrade Support online upgrade Trigger Waveform observation cannot be expanded during normal trigger waiting. Can be used normally during normal trigger waiting. Demo function No Yes Split-screen No Yes Sampling rate Single channel 1G/s, more than 2 channels only 250M/s Single channel 1G/s, 2 channels 500M/s, multiple channels 250M/s Start time 2-3S about 16s Power consumption about 6W about 7.5W How to Connect the Cables? 4pcs x HT 30 test lines 1pc x HT25 secondary ignition pick-up line 1pc x battery clip cable 1pc x USB cable 2pcs x HT201 attenuator 20pcs x piercing needles 2 pairs x multimeter probes 2 pairs x crocodile clips 5pcs x colored 4 female probes 4pcs x clipper fuses(5*20mm) 2pcs x screw head 1pc x user manual 1pc x color label 1pc x packing list
Featuring a new design and upgraded hardware, the LAUNCH O2-2 Scopebox is a versatile and easy to use add-on module that can detects high level faults on various electrical components, such as sensors, acturators and circuits. By integrating with the X-431 series scan tools via O2-2 application, it delivers accurate and conclusive diagnostic faults that enable the shop and technician to enlarge their scan tool's functionality.
O2-2 Highligts:
1. Channels 4
2. Bandwidth 100 MHz
3. Rasing time less than 3.5 ns (typical)
4. 1-year Warranty. 24 Hours NON-STOP Hassle-Free Technic Support
5. LAUNCH Electrical analyzer (oscilloscope) is stable, durable, and portable.
6. Features the ability to record and play back high-resolution waveform data for future analysis;
7. By integrating with the X-431 series scan tools via the O2-2 application, it delivers accurate and conclusive diagnostic faults
8. LAUNCH O2-2 Scopebox can detect high-level faults on various electrical components, such as sensors, acturators and circuits.
9. One-click enable function allows users to capture a particular waveform making the process 70% more efficient compared to other oscilloscopes.
10. Support with X-431 series scan tools and V5.0 new version tools:
- Offline Model: X431 pro3 link, X431 Throttle, X431 Pad II AE, X431 Torque, X431 Turbo
- Online PRO Series Model: X431 Pros Star, PROs Elite/PRO ELITE, X431 PRO (V 5.0, PROS V5.0), X431 V+ V5.0, X431 Pro3S+ V5.0, X431 PRO3 APEX, X-431 PRO3 ACE, X-431 PRO3 (V+) ELITE, X-431 PRO5 SmartLink
- PAD Series Model: X-431 PAD V ELITE, X-431 PAD VII ELITE,
- IMMO Series Model: X431 IMMO Elite, X431 IMMO PLUS
NOTE: DO NOT SUPPORT old version PRO5, CRP919X BT/CRP919E BT, PRO3S+ V2.0, V+ 2.0 or V+4.0.
If you are not sure if your device is supported, please feel free to contact us with your serial number.
Features of Launch O2-S2 Scopebox:
LAUNCH X431 O2-2 Scope Box Functions:
1. Supports multiple vehicle preset project tests
Supports a variety of automotive preset project tests, such as circuits, sensors, actuators, ignition tests, communication tests and combination tests, and presets various parameters and specific connection methods for each test.
2. 23 automatic measurement settings
23 automatic measurement settings are displayed on one screen, which is clear at a glance and can be clicked with a light touch. It supports one-click clearing, eliminating the tediousness of turning pages and searching multiple times, making automatic measurement easy to use and convenient.
3. Quick trigger source switching
Supports edge, pulse, and other triggers. Simple and intuitive trigger settings and fast trigger source switching methods make the most difficult part of oscilloscope application extremely easy.
4. Quickly create waveform preset parameters with one click
When testing waveforms, you can save the existing settings on the current interface as waveform preset parameters with one click. When testing similar waveforms later, you can directly load the preset parameters without repeated settings.
5. Quickly save waveforms with one click
Quickly save the waveform currently displayed on the screen with one click and automatically save it in the specified format. It can be directly used as a reference channel waveform for display later.
6. Convenient cursor operation
Turn on the horizontal and vertical cursors with one click respectively. Each cursor can be dragged independently, and cursor tracking is also directly implemented through simple highlight touches, improving overall efficiency by more than 80%.
7. Support cursor/phase ruler changes accordingly
When the waveform is zoomed in/out, the cursor and phase scale can change accordingly, keeping the measurement range unchanged.
8. Supports 2-point touch, the waveform can be zoomed in or out vertically or horizontally
Drag horizontally or vertically with 2 points to zoom in or out the waveform horizontally or vertically.
9. Support demonstration function
Preset sine waveforms to demonstrate common functions without connecting an oscilloscope.
10. Supports waveform math operations
Supports addition, subtraction, multiplication, and division calculations of two-channel waveforms, in addition to fast Fourier transform.
Detailed Comparison Between Launch O2-2 Scope Box and Launch O2-1 Scope Box :
DC:12V/24V
DC:12V/24V
Different application scenarios require different connection methods (no matter which application scenario, the following connections are required)
1. power the oscilloscope box through the double-clip power cable: Connect one end of the double-clip power cable to the power interface of the oscilloscope box, and the other end to the vehicle battery to draw power (red is connected to the positive pole, black is connected to the negative pole).
Note: * PADVII series tablets support USB power supply.
2. Connect the Type B terminal of the USB cable to the Type B interface of the oscilloscope, and connect the other end to the USB interface of the diagnostic device.
Package Includes:
1pc x Launch O2-2 main unit