| Sensing Distance |
100mm |
300mm |
| Light Source (Wavelength) |
650nm Red Laser |
650nm Red Laser |
| Supply Voltage |
DC 12–24V (ripple p-p ≤10%, DC10–30V allowable) |
DC 12–24V (ripple p-p ≤10%, DC10–30V allowable) |
| Current Consumption |
≤25mA |
≤45mA |
| Control Output |
Load current ≤100mA, residual voltage ≤1V |
Load current ≤100mA, residual voltage ≤1V |
| Circuit Protection |
Surge protection, short-circuit protection, reverse polarity protection |
Surge protection, short-circuit protection, reverse polarity protection |
| Response Time |
Operation / Recovery ≤1.0ms each |
Operation / Recovery ≤1.0ms each |
| Indicator Light |
Red operation indicator lamp |
Red operation indicator lamp |
| Operating Ambient Temperature |
-25℃ ~ +55℃ (no frost/ice); Storage: -40℃ ~ +70℃ (no frost/ice) |
-25℃ ~ +55℃ (no frost/ice); Storage: -40℃ ~ +70℃ (no frost/ice) |
| Ambient Light Limit |
Sunlight ≤10000LX, Incandescent lamp ≤3000LX |
Sunlight ≤10000LX, Incandescent lamp ≤3000LX |
| Ambient Humidity |
Operation: 45%~85% RH (no frost); Storage: 35%~85% RH (no frost) |
Operation: 45%~85% RH (no frost); Storage: 35%~85% RH (no frost) |
| Voltage Influence |
Detection distance variation ≤±1% within ±15% rated voltage fluctuation |
Detection distance variation ≤±1% within ±15% rated voltage fluctuation |
| Insulation Resistance |
≥20MΩ (DC500V megohmmeter, between power circuit & housing) |
≥20MΩ (DC500V megohmmeter, between power circuit & housing) |
| Dielectric Strength |
AC1000V, 50/60Hz, 1min between power circuit & housing |
AC1000V, 50/60Hz, 1min between power circuit & housing |
| Vibration Resistance |
10~50Hz, double amplitude 1.5mm, 1 hour for X/Y/Z axes each |
10~50Hz, double amplitude 1.5mm, 1 hour for X/Y/Z axes each |
| Shock Resistance |
500m/s² double amplitude, 3 times for X/Y/Z axes each |
500m/s² double amplitude, 3 times for X/Y/Z axes each |
| Protection Class |
IP65 |
IP65 |
| Connection Type |
Cable lead-out (standard 2m cable) |
Cable lead-out (standard 2m cable) |
| Housing Material |
PC |
PC |