⚡ IN STOCK

Buckleys Dry Roof Pro DRP01 Flat Roof Leak Detector Kit

SPECIAL OFFER: $4,799.95

Buckleys Dry Roof Pro DRP01 flat roof leak detection system for identifying leaks in non-conductive roofing membranes through controlled electrical test methods.

Detailed Overview

Electrical Leak Detection for Non-Conductive Flat Roof Membranes

The Buckleys Dry Roof Pro DRP01 detects leaks and defects in non-conductive flat roof membranes by establishing an electrical path to earth. The instrument applies controlled DC voltage and identifies faults as the electrode is moved across the membrane surface.

 

Controlled DC Output with Adjustable Sensitivity

  • Output voltage range: 2–40kV DC
  • Alarm sensitivity range: 10–450µA (pre-set to 350µA)
  • Visual and audible alarm indication
  • Built-in test voltage formula: NACE SP0274

Probe and Electrode Configuration

The probe handle connects to interchangeable electrodes, including brush and pointed types. Insulated extension rods increase reach during testing. An earth lead completes the circuit required for detection.

Application

  • Detection of leaks and defects in non-conductive flat roof membranes
  • Testing across a range of membrane thicknesses within specified limits
  • Field inspection using portable, battery-powered equipment

Key Benefits

  • Fully Tested & Certified
  • 30-Day Risk-Free Returns
  • 1-Year Full Warranty
  • Professional Calibration Services
  • Trade-In Program Available
  • Fast & Reliable Delivery

What's in the Box

  • 1 x Buckleys DRP01 Unit
  • 1 x Probe Handle
  • 1 x 75mm Pointed Probe
  • 2 x 332mm Insulated Mid-Section Extension Rod
  • 1 x 321mm Insulated End-Section Extension Rod
  • 1 x 450mm Straight Phosphor-Bronze Brush Electrode
  • 1 x 5m Earth Lead on Reel
  • 1 x 50m Earth Extension Lead
  • 1 x Drum Brush Electrode
  • 1 x Markal B Paintstik (Yellow)
  • 1 x Knurled Thumb-Nut
  • 1 x Test Voltage Calculator
  • 1 x Dry Roof Pro User Instructions
  • 1 x Carry Bag with Shoulder Strap

Technical Specifications

Output Voltage Range 2–40kV DC (2–10kV in 10V steps; 10.1–40kV in 100V steps)
Maximum Output Current Less than 1mA (continuous)
Polarity Positive
Sensitivity Range 10–450µA (preset to 350µA)
Alarm Indicators Audible alarm + red LED
Test Voltage Formula NACE SP0274 (built-in)
Coating Thickness Range 64µm to 25.6mm
Meter Accuracy Voltage: ±1.0% ±1 digit
Current: ±2.0%
Current Meter FSD 450µA
Power Source 4 × D-cell batteries (NiMH or LR20)
Battery Life Approx. 8 hours at 40kV
Battery Indicators LCD battery level (NiMH-calibrated)
Unit Dimensions 172mm (W) × 85mm (H) × 235mm (D)
Unit Weight 1.64kg (generator unit)
Handle Weight 720g
Operating Temperature 0°C to +40°C
Maximum Relative Humidity 80% non-condensing
Operating Altitude Up to 2000m
Display 2×8 character backlit LCD
User Controls Membrane keypad (voltage, sensitivity, alarm volume, formula mode)
Accessories Interface Coiled low-tension probe lead; earth return socket
Included Electrodes Phosphor-bronze brush, stainless-steel drum brush, pointed probe
Extension Rods 2 × mid-section (332mm), 1 × end-section (332mm)
Earth Leads 5m earth lead; 50m earth extension lead
Safety Compliance EMC Directive 2014/30/EU; Low Voltage Directive 2014/35/EU
Calibration Annual calibration recommended (OEM service only)
Full Warranty Protection
1 Year Comprehensive Coverage
(Including Calibration Support & Trade-In Options)
24/7 Customer Support
Contact Us
Toll Free: (833) 322-7865
Local: (469) 470-9378
Email: sales@cartoli.com