The price include:
- Electric floor heating film (width 80 cm), 220V, 112 W/m - 1m (0,8m x 1m), warranty - 10 years;
- Sealing
and isolating tape serve for insulating and fixing electric
circuit connections and contacts;
- instruction.
Experience with these heating films already 18 years!
There have been no defects during 18 years!!!
You can buy any quantity (any other size) of the thermal film and thermal regulators!
Fast delivery to EU countries!!!
If you buy more than 1m, you'll get a discount, but if you buy a roll of thermal film (80 m2), you'll have a great discount!
This film is made in South Korea.
To get more detailed info write me!
e-floor. eu
Technical Data:
- Voltage: 220V
- Width: 80cm
- Cutting step: every 25cm
- Thickness: 0.338mm
- Warm-up temperature: ~ 40°- 41° C degrees
- Guarantee: 10 years
We offer HEATING FILM with 140W/m2, 220W/m2, THERMOSTATS and PEPI REFLEKT POLY material, to find out the price - write me.
Carbon-copper and polymer alloy
films (only 0.3mm thick), integrated under floor surface, make floor in your
apartment (bathroom, hall, nursery, terrace, balcony, etc.) a large radiator,
heating of which uses electric power. Nothing else is needed but to maintain
comfortable temperature (21-34 °C), but - if you want so, it can be higher!
Your floor will always be warm and dry. Summer touch will be in your apartment
longer than just a couple of months each year.
Unlike traditional heating types,
where only air is being heated, which in turn heats objects and living beings
in the room, long heat waves are not only heating the air, but affect living
beings also directly, giving sense of warmth and comfort and also reaching
therapeutic effect. Compared to other electric heating types, over 50% savings are reached. And use of a good
thermal regulator increases this economy even more.
Electronic floor is covered with polymer layer, which provides
for flexibility and protects against minor mechanical damages.
Floor is not subject to corrosion, and polymer deterioration
period is longer than that of concrete!
Electronic floor production technology provides protection
against abstracted lodgers. Even if you will drive an axe into parquet, you
will only be able to damage some square centimeters of the heating surface.
Electricity is safe!
|
|

|
Electric heating is one of the safest heating types.
However, in order to guarantee your safety, better entrust electric
connection to professional electrician. Definitely use only certified
materials - carbon-copper-polymer films and thermal regulators. Special
attention should be paid to the thermal regulator, which not only helps you
save your finances significantly, but also defines electronic floor
operation safety level. In order to make operation more convenient, use
automatic fuse, which will make electronic floor connection/disconnection
much easier, in case you will leave your apartment for longer time.
|
|
This thermal film you
can use under laminated floors, ceramic covering, etc.
Electronic floor installation is very easy!
For example,
Installation of electronic floor for laminate covering:
|
- Floor base
surface must be carefully cleaned from dust and other interfering objects;
- Lay reflecting heat insulation material (Pepi Reflekt
Poli, etc.) Material can be 3–6 mm thick, depending on evenness of prepared
surface. To prevent displacement, material must be fixed on base surface
and sheets must be fixed each to other with construction adhesive tape
(Moment or other);
- Lay carbon-copper polymer film sheets according to
prepared layout. Recommended not to lay it closer than 10 cm to the walls.
Recommended to lay film in longitudinal room direction, minimizing number
of individual sheets, electric connection wires and their connections.
Observe that upper side is that where graphite stripes overlay copper
stripes on sheet edges, during laying. For uniform heating lay sheets as
close to each other as possible, preventing
their overlapping, however. To prevent sheets from moving,
they must be fixed with construction adhesive tape to reflecting material
and between themselves;
- Construct electrical connection of carbon-copper
polymer film sheets. Sheets are connected to power supply (thermal regulator
commutation unit) parallel – it
means that two wires will connect commutation box with each sheet, if only
interconnections were not created. Recommended
to use wires of two different colours, in order to make wire mating in
communication box easier. A number of wire connection solutions are possible.
First, clamps can be used, which must be pressed on wire end without insulation
with flat pliers. Then clamp can be riveted
to copper strip located on film edges. However, we recommend to solder wires to copper strip by using
temperature-resistant solder. Connection places must be carefully insulated with
unvulcanized rubber or bitumen insulation tape (Sika MultiSeal, etc.) In the
same way other ends of copper strips must be insulated, where wires are not
connected. To make surface even, connection places may be submerged in
reflecting material, located under carbon-copper polymer film, cutting out
respective hollows in them. Floor temperature sensor must also be installed.
Sensor must be placed under the film in such way, so that one of carbon (black)
strips was above it. Sensor and its wire must be immersed in insulation
covering and fixed with adhesive tape. Carefully
memorize sensor location place, as no objects may be located on the floor above
it. Wire connections in commutation box, as well as thermal regulator
connection (according to the scheme provided) should be executed by qualified
electrician;
-
After examining the circuit, power supply must be connected. If film sheets
don`t heat up, or don`t heat up uniformly, seek defect in electrical circuit;
- Film sheets must be covered with moisture protection
material, e.g., polyethylene film, in order to provide additional protection
against moisture;
- Start laying laminated floor. Important!!!
In choosing laminated parquet seek some designations
indicating that this laminated floor may be used with heated floors. Laminated parquet should be
kept unpacked at room temperature for at least one week. After laying
adjust maximum floor temperature to max. 20 °C for few days, then gradually
increase it, if necessary. Otherwise, if you will lay cold laminated
parquet and rapidly increase its temperature, it will deform. As maximum
temperature for laminated floors is recommended 29 °C, however, if
laminated floor was glued, then higher temperatures will not damage it. Placing objects on the
floor will hinder heat exchange, cause rapid laminated parquet temperature
rise and possible deformation.
|
|