Features

Universal AC input (up to 305VAC) / Full range
High efficiency up to 90.5%
Built-in active PFC function, PF> 0.9 for 60% of load or higher
Protections: Short circuit / Over current / Over voltage / Over temperature
IP67 / IP65 design for indoor or outdoor installations
Class 2 power unit
Output current adjustable through output cable or internal potentiometer
Cooling by free air convection
Suitable for dry, damp and wet location
Suitable for LED lighting and street lighting applications
Meet 4kV surge immunity level (IEC61000-4-5)
Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) Blank-Type: IP67 rated. Cable for I/O connection D-Type(option): IP67 rated. Timer dimming function, contact MEAN WELL for details.
7 years warranty

General Specification 

AC input voltage range 90~305VAC ; 127~431VDC
AC inrush current (max.) Cold start, 50A at 230VAC
DC adjustment range ±10% rated output voltage (A-Type only)
Current adjustment range 60%~100% rated output current adjustable by internal potentiometer (A-Type only)
Over current protection 95%~108% constant current limiting, auto-recovery
Over voltage protection 109%~145% rated output voltage, shut off, re-power on to recover
Setup, rise, hold up time 1000ms, 80ms, 16ms at full load and 230VAC
Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC
Working temperature -40~+70ºC (refer to output derating curve)
Safety standards UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1
EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Connection Input UL rated, SJTW 18AWGx3C (30cm)
Connection Output A/D/Blank-Type: SVT 18AWGx2C (30cm); B-Type: SVT 18AWGx2C (30cm)+UL2517 18AWGx2C (30cm)
Dimension (LxWxH) (mm) 171x 61.5x 36.8