| AC input voltage range |
90~264VAC ; 127~370VDC |
| AC inrush current |
Cold start, 45A at 230VAC |
| Overload Range |
>105% rated output current |
| Protection Type |
Hiccup up mode, auto-recovery |
| Over voltage protection |
110%~145% rated output voltage |
| Withstand voltage |
I/P-O/P: 3kVAC |
| Working temperature |
-30~+70°C (refer to output derating curve) |
| Vibration |
10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes |
| Safety standards |
UL8750 approved (except for APC-25-350&APC-35-350/500);Design refer to TUV EN60950-1 |
| EMC standards |
EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11 |
| Connection Input |
UL rated, 18AWGx2C (15cm) |
| Connection Output |
UL rated, 18AWGx2C (15cm) |
| Dimension (LxWxH)(mm) |
84x 57x 29.5 |