ETB1786 Glossmeter coating and woodwork Gloss meter 0-200GU Testing Instrument
1. Brief Introduction
The technology parameter of ETB1786 Glossmeter is complete according with state standard GB9754-88,GB9966.5 and international standard ISO2813, all items of the performance meet the first class work requirements of state JJG696-2002 (Lens Luster Degree Instrument Measure Test Regulations)
2. Applications
1.The surface luster measure for printing ink, paint, bake lacquer, coating and woodwork
2.The surface luster measure for construction decoration materials: marble; granite; glass
chemical polishing brick and pottery brick
3.The surface luster measure for plastic and sheet
4.The surface luster measure for other non-metal materials
3. Instrument Characteristics
1.Fine, light stylish appearance, easy to carry
2.Completely intelligentized design, single key operation, convenient to use
2.Automatic adjustment, no need to be hand adjustment
3.Multi-angles, choose what you want
4.Long life-span lamp- house, no need to change
5.Precise measure, excellent repetition performance
6.LCD digital display, with backlight, accurately display the remainder of the battery
7.There is buzz sound during operation
8.Turn off automatically
9.USB interface, can save 1245 datas and can check the time
4. Technology parameter
1. Measure range: 0-200GU
2. Stability: <±0.4 GU/30Min
3. Value error: <±1.2GU
4.Power: 1.5V
5. Projecting angle: 60°
6. Environment temperature: 0-40℃
7. Relative humidity: ≤ 85%
8. The Measuring window size: 11×35mm
9. Dimension:136*91*46(mm)
10. Weight: 380 g
5. Display instructions
1. “GU”--- luster unit
2. “calibrate”---calibration
3. “clear save”---clear the save datas.
4. Change Ca”l--- Modify the calibration value
5. ”Set time”---Modify the time
6. Direction
Press the “key”(on the side of the gauge) to start the gauge
The gauge display “calibrate ?” , take the gauge into the calibration-case, and press the “key” to confirm adjustment operation, the gauge will distinguish the state board automatic and there is buzz sound to prompt, when “calibrate ok” display on the screen, 2 seconds later, the gauge is on “working condition” and the screen display “ready“.
Take the gauge away from the calibration-case, and put the gauge on the measured object, appoint the measure window to the measured object, press the “key”, the gauge begin to measure, the luster value of the measured object will display on the screen while there is buzz sound.
1 second later, if there isn’t any other operation, the gauge will turn off automatically,,or press the “key”until display nothing then release it,the gaguge will turn off.
7.The display of the menu
When the gauge is on working condition, press the key until display “SET MENU”then release it, the gauge is on menu-setting, the display is as bellow:
The cursor(Anti eplicit state) is circling on the menu, when the cursor is on the option, press the “key”, and you can perform the option.
8.Modify the calibration value
If you want replace the stand board(black quartz crystal board), and you have to modify the calibration value. On the main menu, when the cursor show on “Change CAL”, press the “key”, the gauge is on “Modify the calibration value” and the screen show “Change CAL?”, if you need to modify the calibration value, press “key” to confirm and begin to perform the process, (if you need’t to modify, don’t to do anything, 2 seconds later, the gauge return the working condition). after you pressing the key, and the data begin plus from 80. When the new calibration value was confirmed, the setting (modify the the calibration value) will be finished and the gauge will be on working condition.
9.Setting time
On the main menu, when the cursor shows on “Set time”, press the “key”, and begin to set time, the cursor indicator is where you want to modify, when the data is changed to the predetermined value, press the “key”to confirm. And the cursor move to the next position, if press the “key”twice,the cursor more to the last position, repeating the process and finished the setting time.
10. Matters required attention
(1). It should avoid strong light direct radiation; or it will affect the measure precision.
(2). The standard board of the gauge should be kept clean, please do not touch the surface with fingues. If there is dirt on the surface, the measure precision will be affected. Wipe it with lens cloth or absolute alcohol.
(3). When the battery is less than 20%, which needs to change battery. Open the battery cover, replace the old battery with the new one, please pay attention to the joint line polarity.
(4)The battery should be changed when it runs up, otherwise, it stored for a long time may flow the liquid which cause damage of the instrument. It should be taken out and keep proper if it is not used for a long time.
11.Services
This instrument has one-year quality guarantee, maintenance for all life. If there are any problem of this product, please contact the dealer in time.
INTERNATIONAL SHIPPING:
The package will be shipped by DHL, FEDEX or EMS. After we shipped the parcel,we'll fill in the tracking number.
Please write the correct address and telephone number when you make orders,so the courier can contact you when they deliver the parcel to you. thanks
CUSTOMS CLEARANCE
1.We always make lower amount on invoice, if you need one different, please leave us a message.
2.The buyer is responsible for any tax and/or duty charged by their country.
PAYMENT INFORMATION:
1.We can accept Paypal,T/T,Credit Cards and so on.
WARRANTY INFORMATION:
1.All the products have been checked and packed in good condition before dispatch.
2.All the products with one year warranty.
3.If you find any quality problems,please send it back within 3 days,and we'll send you a new one or refund you the payment after we get the returned one.
4.Buyers have to pay for the return cost and we will pay the cost for resend
5.All products returned should be in new conditions.
FEEDBACK:
1.A good feedback is very important for our store,if you feel satisfied with our products,please give us positive feedback.
2.Please contact us before leaving any negative or neutral feedback,We will work with you to solve any problems.