SPECIFICATION
Instructions on the usage conditions of SW100 and SW200 series G4 products
- Input/Output Power: 1.5KW
- Input Voltage: Single phase 240V
- Output Voltage: Three phase 415V
- Input/Output Current: 4A
- Input Frequency: 50/60 Hz
- Output Frequency: 0-600 Hz
- Dimension:173*65*151mm (L x W x H)
SW100 and SW200 series G4 products sold with 1 years replacement warranty!
For more information about SW100 and SW200 series G4 products, please check the following downloads:
- Sowakam100 Manual, Please CLICK HERE to download.
- Sowakam100 Brochure, Please CLICK HERE to download.
- Sowakam100 CE Certification, Please CLICK HERE to download.
- Sowakam100 Maintenance Instruction, Please CLICK HERE to download.
DESCRIPTION
The G4 series products is single phase AC 240V input and three phase AC 415V output.
The voltage boosts up via capacitors, not the transformer. This is a CUSTOM DISIGNED product indicated to use with AC induction motor at limited conditions.
- The VFD can only drive AC induction motors directly. It CAN NOT provide three phase AC power for equipment other than motors.
- Do not connect the VFD output terminal U.V.W to the three phase 415V power distribution system or electrical devices. This VFD CAN NOT to be used as a three phase 415V power source
- It is not allowed to install a AC contactor/relay between the motor and the inverter.
- Do not directly supply power to the motor through the contactor/relay, air switch, or circuit breaker when the inverter output frequency reaches the maximum frequency to avoid damage to the VFD due to over-current.
For G4 series products, it is recommended that the load be light-loaded when driving the motor. If the load is heavy-loaded, it is recommended to increase the size of the VFD.
For example: If the load used is a heavy-duty three phase motor with a power of 0.75KW, then the recommended VFD power is a three phase 1.5KW unit.