Features
- Operates as a field satellite controller for the Maxicom2
and SiteControl central control systems.
- Advanced contamination-resistant design to assure reliable
performance.
- Heavy-duty electrical surge protection.
- 12-hour watering duration for any or all stations to aid in
drip compatibility.
- Four programs with eight start times each allow mixed
irrigation applications in a single controller.
- Two master valve terminals, one programmable by station,
provide better control.
- Programs can overlap to maximize hydraulic capacity and
minimize watering time.
- 365-day calendar with leap year intelligence for one-time
date and time setting.
- Event day off option to set any day of the month as a
non-watering day for all programs.
- Programmable rain delay enables system to stay off for
specified period with auto-restart.
- Independent day cycle by program. •Water budget by program
provides adjustments from 0-300% in 1% increments.
- Cycle+Soak by station allows total irrigation run time to be
split into usable cycles, minimizing runoff.
- Manual watering by station or program.
- Sensor override switch with LED to indicate when irrigation
is suspended.
- Non-volatile, 100-year memory holds program, date, and time
during power outages.
- Automatic fault indication identifies electrical shorts,
skips shorted stations, and continues watering remaining program.
- Quick-connect terminal strip speeds installation.
- Universal remote ready: pre-installed connectors for
addition of remote products.
- Heavy-duty transformer for simultaneous operation of up to
nine 24 VAC, 7VA solenoids.
- Battery-programmable controller allows for programming prior
to installation.
Stand-Alone Operating Specifications
- Station timing: A, B, C, D: 0 to 2 hours in
- 1-minute increments;
2 to 12 hours in 10-minute increments
- Automatic starts: 32 starts total, eight per program per day
- Programming schedule:
ODD day watering per program;
EVEN day watering per program
CYCLICAL (1 to 99 days, variable per program;
Custom day-of-the-week by program
Test program: Variable 1 to 99 minutes
Operating Specifications
(Central Control Operation)
- Requires a CCU to connect to Maxicom2 central controller
- Requires a TWI to connect to SiteControl central controller
- MAXILink™ models have 2 sensor inputs - no decoders required
- 40 station models require 2 CCU channels.
Electrical Specifications
- Input required: 117 VAC ± 10%, 60Hz (International models: 230 VAC± 10%, 50Hz)
- Output 26.5 VAC, 2.5A
- Station load capacity: Up to two 24 VAC, 7VA solenoid valves
per station (up to 4 stations operating simultaneously) plus a master valve or
pump start relay
- Diagnostic circuit breaker skips and indicates stations with
overloaded circuits
- Battery backup: 9VDC, NiCad rechargeable for programming
under battery power and for maintaining active program-in-progress during a
power outage •Heavy-duty electrical surge protection
Dimensions Metal Wall Mount
- Width: 115⁄16" (28,7 cm)
- Height. 11½" (29,2 cm)
- Depth: 6 ½" (16,5 cm)