Skein Networking Cable Shielded Outdoor FTP Cat. 5e up To 1Gbps Copper Pure Lan
The description of this item has been automatically translated. If you have any questions, please feel free to contact us.
Pure copper outdoor shielded network cable
For all applications where the laying of the LAN network cable in an external environment is required and transfer speeds up to 1Gbps.
| CPR |
Fire reaction class Fca |
| Standards |
ISO/IEC 11801, IEC 61156-5, EN 50173-1, EN 50173-2, EN 50288-2-1/EN 50288-3-1 |
| Type of conductor and dimensions |
Copper 0.50 mm ± 0.005 mm |
| Isolation |
HDPE |
| Diameter of conductor with insulation |
1.0mm |
| Cable diameter |
6.2mm |
| Weight |
40kg/km |
| Color |
Black RAL 9005 |
| nvp |
68% |
| Propagation delay |
535ns/100m |
| Skew delay |
≤ 45ns/100m |
| Storage temperatures |
-20 to +60 °C |
| Operating temperatures |
-20 to +60 °C |
| Installation temperatures |
0 to +50 °C
|
| Transmission characteristics (at 20 °C) |
| f (MHz) | Attenuation (dB/100m) | NEXT (dB) | PSNEXT (ns/100m) | Prop. delay (ns/100m) | ACR-F (dB/100m) | PSACR-F (dB/100m) | Return loss (dB) |
|---|
| 1 |
1.94 |
83.24 |
82.43 |
534.95 |
76.30 |
72.75 |
32.03 |
| 4 |
3.89 |
71.20 |
69.89 |
516.29 |
64.02 |
60.40 |
33.38 |
| 8 |
5.52 |
68.88 |
66.19 |
510.89 |
58.02 |
53.00 |
35.09 |
| 10 |
6.18 |
69.88 |
66.88 |
509.48 |
55.08 |
51.28 |
36.05 |
| 16 |
7.83 |
66.11 |
63.11 |
507.05 |
52.09 |
49.08 |
43.10 |
| 20 |
8.77 |
66.90 |
63.82 |
506.03 |
49.66 |
46.58 |
41.27 |
| 25 |
9.81 |
65.40 |
60.58 |
505.18 |
43.65 |
41.21 |
40.07 |
| 31.25 |
11.00 |
57.77 |
55.07 |
504.40 |
45.14 |
52.54 |
39.08 |
| 62.5 |
15.67 |
53.31 |
51.59 |
502.45 |
38.30 |
35.30 |
34.07 |
| 100 |
19.86 |
52.37 |
50.12 |
501.44 |
34.68 |
31.91 |
33.31 |
Pure copper outdoor shielded network cable For all applications where the laying of the LAN network cable in an external environment is required and transfer speeds up to 1Gbps. Fire reaction class Fca Standards ISO/IEC 11801, IEC 61156-5, EN 50173-1, EN 50173-2, EN 50288-2-1/EN 50288-3-1 Type of conductor and dimensions Copper 0.50 mm ± 0.005 mm Isolation Diameter of conductor with insulation Cable diameter Weight 40kg/km Black RAL 9005 Propagation delay 535ns/100m Skew delay ≤ 45ns/100m Storage temperatures -20 to +60 °C Operating temperatures -20 to +60 °C Installation temperatures 0 to +50 °C Transmission characteristics (at 20 °C) f (MHz) Attenuation (dB/100m) NEXT (dB) PSNEXT (ns/100m) Prop. delay (ns/100m) ACR-F (dB/100m) PSACR-F (dB/100m) Return loss (dB) 534.95 516.29 510.89 509.4
| Connettore A |
Cat 5e |
| Marca |
Solarix |
| Tipo |
Cavo di rete |