User-friendly pen type tester
・Perfect fit in hand with overmold
・Equipped with an LCD backlight that allows you to check the value in a dark place
・Uses a long-life LED light that brightly illuminates the measurement target
・The measurement cord can be stored smartly in the back of the main unit.

■ Specifications ■
[DC voltage] 400.0mV/4.000/40.00/400.0/600V (5 range auto), (input impedance: 10MΩ)
_Accuracy_±0.8%rdg±5dgt (400.0mV to 400.0V)
______±1.0%rdg±5dgt(600V)
[AC voltage] 4.000/40.00/400.0/600V (4 ranges, auto), (input impedance: 10MΩ)
_Accuracy_±1.3%rdg±5dgt(4.000/40.00V)(50/60Hz)
______±1.6%rdg±5dgt(400.0/600V)(50/60Hz)
[Resistance] 400.0Ω/4.000/40.00/400.0kΩ/4.000/40.00MΩ (6 range auto)
____±1.0%rdg±5dgt(400.0Ω~4.000MΩ)
______±2.5%rdg±5dgt(40.00MΩ)
[Continuity] Buzzer sound at 120Ω or less
[Diode] Open voltage: about 1.5V (0.4mA measurement current)
[Capacitance] 50.00/500.0nF/5.000/50.00/100.0μF (5 range auto)
_Accuracy_±3.5%rdg±10dgt(50.00nF)
______±3.5%rdg±5dgt (500.0n to 50.00μF)
______±4.5%rdg±5dgt(100.0μF)
[Frequency] 5.000/50.00/500.0Hz/5.000/50.00/200.0kHz
_Accuracy_±0.1%rdg±5dgt
______ (Input sensitivity current: 1.5V [~50kHz] / Voltage: 10V [>200kHz] or more)
[Duty] 0.1 to 99.9%
_Accuracy_±2.5%rdg±5dgt (pulse width/pulse period)
[Data hold] Operates when the data hold button is ON
[Battery level warning] Warning display at about 2.4 V or less
[Compliant standards] IEC61010-1CATIII600V pollution degree 2, IEC61010-031, IEC61326 (EMC)
[Battery used] Alkaline button battery LR44 (1.5V) x 2 (auto power off about 30 minutes)
[External dimensions] 190 (L) x 39 (W) x 31 (D) mm
[Weight] Approx. 100g (including batteries)
[Accessories] Carrying case, alkaline button battery LR44 (1.5V) x 2, instruction manual