2/0 AWG 600V COPPER WELDING CABLE BLACK 5ft LENGTH MADE IN USA
.
Available Quantity: 1
Cable Length: 5ft
Cable Color: Black
.
Royal® EXCELENE® NON-UL Welding Cable, Silicone Free
600 Volt 105°C Flexible Cord, Heat, Abrasion, Tear Resistant, Moisture and Flexible EPDM Jacket
.
GENERAL CABLE DESCRIPTION
2/0 EXCELENE WELDING CABLE WITH A HIGH FLEXIBILITY AND IS RATED FOR 600V, CAN BE USED AS LEADS FOR A WELDER OR BATTERY CABLES FOR MACHINERY. (ROHS
COMPLIANCE) MADE IN USA
.
CABLE TECHNICAL SPECS
2/0 WELDING CABLE
CONDUCTORS: BARE
COPPER STRANDING: 1254
JACKET: EPDM
O.D: 0.570"
AMPS: 300
VOLTS: 600V
TEMP: -50*C TO 105*C (-58*F TO 221*F)
.
HIGH DIELECTRIC STRENGTH INTEGRITY RESISTANCE TO FLAME, OIL, GREASE SOLVENTS, OZONE AND ABRASION, (ROHS COMPLIANCE)
.
CABLE CONSTRUCTION
1. Conductor: Annealed rope-stranded Class K, bare copper conductor as per ASTM B-3. 30 AWG rope lay strand per ASTM B-172
2. Separator: Paper separator for ease of stripability
3. Insulation: EPDM, Black (Other colors available upon request)
.
APPLICATIONS AND FEATURES
Southwire Excelene Welding cable, Extra Flexible, rated for -50°C to 105°C temperatures. This cable used for secondary voltage resistance welding cable leads, National electrical code Article 630 electric welders and for temporary power industrial applications.
.
CABLE SPECIFICATIONS
RoHS Compliant Lead-Free, Silicone-Free
.
CABLE WEIGHTS AND MEASUREMENTS
Cond. Size 2/0 AWG/Kcmil
Cond. Number Count 1
Cond. Strands # x AWG 1254
Insulation Thickness 84 mil
Approx. OD 0.570 inch
Approx. Weight 467 lb. /1000ft
Ampacity * 300 Amp
.
CABLE WEIGHTS AND MEASUREMENTS (METRIC)
Cond. Size 2/0 AWG/Kcmil
Cond. Number Count 1
Cond. Strands # x AWG 1254
Insulation Thickness 2.13 mm
Approx. OD 14.48 mm
Approx. Weight 695 kg/km
Ampacity * 300 Amp
.
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
* Ampacities are based on TABLE 400.5(A) of the 2017 National Electrical Code and CEC Table 12. The Ampacity values assume a continuous sinusoidal 60 Hz current and are for reference only and should not be used as a final value.
^ No metric print legend
.
EXTENDED INFORMATION
| AMPS | 50’ | 100’ | 150’ | 200’ | 250’ | 300’ | 350’ | 400’ | 450’ | 500’ |
| 100 | 4 | 4 | 4 | 2 | 2 | 1 | 1/0 | 1/0 | 2/0 | 2/0 |
| 150 | 4 | 4 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 | 4/0 | 4/0 |
| 200 | 2 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | 250 | 250 | 350 |
| 250 | 2 | 2 | 1/0 | 2/0 | 3/0 | 4/0 | 250 | 350 | 350 | 350 |
| 300 | 1 | 1 | 2/0 | 3/0 | 4/0 | 250 | 350 | 350 | 500 | 500 |
| 350 | 1/0 | 1/0 | 3/0 | 4/0 | 250 | 350 | 350 | 500 | 500 | 500 |
| 400 | 2/0 | 2/0 | 3/0 | 250 | 350 | 350 | 500 | 500 | 500 | |
| 500 | 3/0 | 4/0 | 4/0 | 350 | 350 | 500 | 500 | |||
| 600 | 4/0 | 4/0 | 250 | 350 | 500 | 500 | ||||
| 700 | 350 | 350 | 350 | 500 | 500 | |||||
| 800 | 350 | 500 | 500 | 500 | ||||||
| 900 | 500 | 500 | 500 | 500 | ||||||
| 1000 | 500 | 500 | 500 | |||||||
RECOMMENDED MINIMUM WELDING CABLE SIZING CHART
Ampacities are based on 105*C conductor temperature, 40*C ambient air/50% duty cycle and approximate voltage drop of 4v @ 25*C conductor temperature of 5VB @ 105*C conductor temperature.
Length in feet for total circuit for secondary voltages only (DO NOT USE THIS TABLE FOR 600 VOLT IN-LINE APPLICATIONS)
| ||||||||||
EBILC 252