Refurbished 4 kVA Power Module for Symmetra LX Systems - Full Capacitor Replacement
This 4 kVA Power Module (APC Part Number: SYPM4K) has been expertly refurbished with a complete capacitor replacement and a refresh/replacement of all critical wear items. Each unit is serviced in our professional electronics lab by experienced engineers to ensure the highest level of reliability and performance.
As a four-decade industry veteran, Gruber Power pioneered the refurbishment of critical power equipment modules like this. Our meticulous rebuild process includes full load bank testing in our UPS Depot Operations, simulating worst-case conditions to validate proper operation under real-world loads.
Our Critical Power Module rebuild process resets the module to factory specifications and optimal performance, prolongs service life, and reduces the risk of unplanned downtimeβat a fraction of the cost of a brand-new replacement. Backed by our full 1-Year Warranty, this refreshed power module delivers dependable performance and peace of mind for mission-critical APC Symmetra LX systems.
All capacitors replaced along with fans and critical wear items for like-new performance
Full worst-case peak demand testing in our UPS Depot Operations facility
Industry-leading warranty coverage backed by 40 years of refurbishment expertise
| Option | Description | Warranty |
|---|---|---|
| Tested | Operationally verified power module. Passed load bank testing and QC inspection without component-level refurbishment. | 90-Day |
| Refurbished | Fully rebuilt with new capacitors, fans, and other wear items. Reconditioned to like-new performance and appearance. | 1-Year |
| UPS Model | Form Factor | Compatible Module | Std. Modules | Max Modules | Usable kVA (Std β Max N+1) |
|---|---|---|---|---|---|
| SYA4K8P | Tower (208/240 V) | SYPM4K (4 kVA) | 1 | 3 | 4 β 8 (N+1) |
| SYA4K8RMP | Rack 13U (208/240 V) | SYPM4K | 1 | 3 | 4 β 8 (N+1) |
| SYA8K8P | Tower (208/240 V) | SYPM4K | 2 | 3 | 8 β 8 (N+1 with 3rd) |
| SYA8K8RMP | Rack 13U (208/240 V) | SYPM4K | 2 | 3 | 8 β 8 (N+1 with 3rd) |
| SYA8K16P | Tower (208/240 V) | SYPM4K | 2 | 5 | 8 β 16 (N+1) |
| SYA8K16RMP | Rack 19U (208/240 V) | SYPM4K | 2 | 5 | 8 β 16 (N+1) |
| SYA12K16P | Tower (208/240 V) | SYPM4K | 3 | 5 | 12 β 16 (N+1) |
| SYA12K16RMP | Rack 19U (208/240 V) | SYPM4K | 3 | 5 | 12 β 16 (N+1) |
| SYA16K16P | Tower (208/240 V) | SYPM4K | 4 | 5 | 16 β 16 (N+1 with 5th) |
| SYA16K16RMP | Rack 19U (208/240 V) | SYPM4K | 4 | 5 | 16 β 16 (N+1 with 5th) |
| SYA16K16PXR | Tower (Ext. Run) | SYPM4K | 4 (incl.) | 5 | 16 β 16 (N+1) |
Important Note: Symmetra LX modules (SYPM4K) are not interchangeable with first-generation Symmetra Power Array modules (SYPM) or Symmetra RM modules (SYPM2KU).