Electrical Specifications at Ta=25C
Parameters Test conditions Downlink Uplink Units
Work Band at –3dB 2155.0-2170.0 1965.0-1980.0 MHz
BandWidth at –3dB 15 15 MHz
Parameters Test conditions Min Typ Max Min Typ Max Units
OutPut power (1 carrier) TS 25.143 V6.0.0 +10 10 dBm
1OutPut power (2 carriers) TS 25.143 V6.0.0 +7 +7 dBm
IP3 Two equal carries +25 +25 dBm
Input sat. Level (1 carrier) 1 carrier -20 -20 dBm ± 2.7 MHz ± 3.5 MHz Units
Out of band gain (Ref. 60dB)
Min Typ Max Min Typ Max
Uplink 60 45 dB
Downlink 60 45 dB
Parameters: Minimum Typical Maximum
Uplink Gain (automatically
adjusted with DOWN_LINK level). 30 50 60 dB
Downlink Gain (automatically
adjusted, max set by SWITCH) 30 50 60 dB
In band ripple ±2 dB
ALC window 60 dB
Uplink excitability -85 dBm
Downlink excitability -85 dBm
Noise factor 7 dB
In / out impedance 50 W
Return losses -12 dB
Group Delay 2 ms
Power supply AC levels 100 220 240 Vac
Power consumption 10 W
Mechanical and Environmental Specifications
RF connectors SMA Female
MTBF 70000 Hours 3GPP TS 25.143 V 6.0.0
Temperature range 0ºC to 45ºC
Package Dimensions (mm) W x H x D 80 X 120 X 30 mm..