| Range | ComPact |
|---|---|
| Range of product | ComPact NSX100...250 |
| Product or component type | Trip unit |
| Trip unit name | MicroLogic 6.2 E |
| Trip unit technology | Electronic |
| Range compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX250 |
| Device application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LSIG |
| Protection type | L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection |
| Trip unit rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
|---|---|
| [Ir] long-time protection pick-up adjustment range | 40...100 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15…400 s at 1.5 x Ir 0.35…11 s at 7.2 x Ir 0.5…16 s at 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0…0.4 s I²t=off 0.1…0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In Compact NSX250 1.5...15 x In Compact NSX100 1.5...15 x In Compact NSX160 |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In for In = 40 A 0.2...1 x In for In > 40 A Ig enable on/off |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0…0.4 s I²t=off 0.1…0.4 s I²t=on |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | With |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Display type | LCD display |
| Type of measurement | Energy meter |
| Communication of data | Time-stamped histories and event tables Power quality Demand current and power Protection and alarm settings Maximeters/minimeters Maintenance indicators Instantaneous and demand values Energy metering |
| Electrical data recording | Maintenance indicators |