Schneider Electric LC1E50M5 EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 50A - 220 V AC coil



The Schneider Electric LC1E50M5 EasyPact TVS contactor is a 3-phase AC-3 rated contactor with a maximum amperage of 50A and a coil voltage of 440V. It features a DIN rail mount and is designed for standard IEC use. With features like non-reversing and black current protection, this contactor is suitable for various electrical applications requiring reliable and efficient control of up to 40 horsepower motors. Its dust-resistant design ensures durability and performance even in challenging environments.

Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current50 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
70 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50 Hz
Complementary
Motor power kW11 kW at 220/230 V AC 50/60 Hz
22 kW at 380/400 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
33 kW at 660...690 V AC 50/60 Hz
Pole contact composition3 NO
[Ith] conventional free air thermal current70 A (at 55 °C) for power circuit
Irms rated making capacity650 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity425 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current400 A 40 °C - 10 s for power circuit
208 A 40 °C - 60 s for power circuit
84 A 40 °C - 600 s for power circuit
Associated fuse rating100 A gG at <= 690 V coordination type 1 for power circuit
10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Average impedance1.5 mOhm - Ith 70 A 50 Hz for power circuit
Power dissipation per pole3.8 W AC-3
7.4 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability5000000 cycles
Electrical durability350000 cycles AC-1
900000 cycles AC-3
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50 Hz
0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA160 VA 50 Hz cos phi 0.75 (at 20 °C)
140 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)
13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W for control circuit
Operating time20...26 ms on closing
8...12 ms on opening
Maximum operating rate1200 cyc/h 60 °C
Connections - terminalsPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 5 N.m
Auxiliary contact composition1 NO + 1 NC
Minimum switching voltage17 V for auxiliary contact circuit
Minimum switching current5 mA for auxiliary contact circuit
Insulation resistance> 10 MOhm for auxiliary contact circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportPlate
DIN rail