# Etracer quick-test report
# Test configuration file:6SN7.etd
# Date and Time: 2026-07-13 13:03:39
============== Test Setup ==============
HV1: 250V, swing: 5%
HV2: Linked to HV1, 100%
NEGV: -8.00V, swing: 5.00%
=========== Measurment Data ===========
# (NEGV(V),HV1(V),HV1_I(mA),HV_2(V),HV2_I(mA))
(-7.60,237.46,11.46,237.48,12.01)
(-7.60,249.99,13.35,250.01,14.00)
(-7.60,262.46,15.31,262.52,16.10)
(-8.00,237.59,10.39,237.49,10.92)
(-8.00,249.99,12.20,250.02,12.84)
(-8.00,262.51,14.11,262.44,14.86)
(-8.40,237.52,9.34,237.54,9.85)
(-8.40,250.00,11.08,249.98,11.70)
(-8.40,262.53,12.92,262.44,13.64)
========= Section 1 Parameters =========
current:12.20 mA, reference:9.00 mA, percent: 135.6 %
rp:6712 ohms, reference:7700 ohms, percent: 87.2 %
gm:2839 umhos, reference:2600 umhos, percent: 109.2 %
mu:19.1 V/V, reference:20.0 V/V, percent: 95.3 %
========= Section 2 Parameters =========
current:12.84 mA, reference:9.00 mA, percent: 142.7 %
rp:6338 ohms, reference:7700 ohms, percent: 82.3 %
gm:2878 umhos, reference:2600 umhos, percent: 110.7 %
mu:18.2 V/V, reference:20.0 V/V, percent: 91.2 %