Designed to control booster pumps, typically mounted near an RO pressure tank
Controls tank pressure when full – not the pressure at pre-filters or membrane
Pressure at the membrane/pre-filters is higher than at the tank
Normally closed design, factory pre-set at various shut-off pressures
Can be reconfigured to normally open by modifying the wire terminal connector
Includes modular plug-and-play connector for easy integration with Aquatec pumps and components
Preset at 100 PSI (adjustable range)
1/4" John Guest quick-connect fittings for easy tubing installation
Made in the USA by Aquatec
Part Numbers: PSW2100-00, PSW-2100
Key Features:
Inexpensive
Compact design
High reliability
100% factory tested
Built-in John Guest half cartridges for easy installation