Double Clamp Earth Ground Resistance Tester with Soil Resistance 0.00ΩM~9000KΩM

Overview:

    This Double Clamp Earth Resistance Tester, through a variety of methods measuring earth resistance (range: 0.01Ω ~ 30.00 kΩ), soil resistivity (range: 0.01Ωm ~ 9000kΩm), earth voltage (range: 0.1 V ~ 100.0 V), grounding lead leakage current, AC current (range: 0.01mA ~ 600A); The tester adopts the precision 4-wire method, 3-wire method, simple 2-wire method, selection method and double-clamp method to measure grounding resistance. Large caliber current clamp design, can measure the grounding system which using large grounding down lead.It can flexibly and accurately measure arbitrary grounding resistance values of single point and mesh grounding and other complex grounding conditions. When measuring parallel grounding, it is unnecessary to disconnect any parallel grounding electrode to maximize the convenience of measurement. Import FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, ensure the measurement of  high precision, high stability and reliability.

    

This Double Clamp Multi-function Grounding Resistance Tester is composed of host machine, current clamp, monitoring software, test wires, auxiliary ground rod and communication cable. Host machine with large LCD display, white backlight, bar chart indication, clear at a glance. It can store 2000 sets of data at the same time, through the monitoring software to relize historical access and online real-time monitoring functions, dynamic display, alarm indication and auto shut down, with historical data reading, accessing, saving, reporting, printing and other functions.


Specification:


Technical Parameters

Function

Description

 Power Supply

 DC 9V Alkaline dry cell LR14 1.5V*6PCS, continues standby 300 hours

 LCD Size

 124mm x 67mm(with backlight)

 Range

 Selection measurement method :0.01Ω - 3000Ω

 Double clamp measurement method :0.01Ω - 100Ω

 2/3/4 pole measurement method :0.01Ω - 30.00kΩ

 Soil Resistivity :0.01Ωm - 9000KΩ

 DC Resistance:0.01Ω - 30.00kΩ

 Earth Voltage:0.1V -100.0V

 AC Current:0.01mA -600A

 Resolution

 Resistance:0.01Ω

 Soil Resistivity :0.01Ωm

 Current:0.01mA

 Voltage:0.1V

 Max Accuracy

 ±2%rdg±3dgt

 Data Storage

 2000 groups

 Data Upload

 RS232 interface, storage data can be uploaded to computer, saved or printed.

 Automatic Shut Down

 Automatically shut down after 15 minutes start up

 Power Consumption

 Turn on the backlight: 45mA Max

 Turn off the backlight : 25mA Max

 Measurement: 100mA Max(Backlight shut off)

 Working Temperature & Humidity

 -10℃-40℃, below 80%rh

 Storage temperature & humidity

 -20℃-60℃, below 70%rh

 Clamp Caliber

 Φ68mm

 Measuring Method

 2/3/4 pole measurement method: Change-pole method, measurement current 20mA Max

 Selection measurement method: Change-pole method, measurement current 20mA Max

 Double clamp measurement method: Non-connect mutual inductance method, measurement current 1mA Max

 Soil Resistivity: 4-pole measurement (Wenner method)

 AC current: Mutual inductance method(clamp)

 Earth Voltage: Average rectification(between P(S)-ES)

 Test Frequency

 128Hz/111Hz/105Hz/94Hz(AFC)

Data Model

 Average value,maximum,minimum value

 line resistance check

 Automatic calibration

 Measuring Rate

 AC current: about 0.5 times/second

 Earth Voltage: about 0.5 times/second

 Earth resistance,soil resistivity: about 5 seconds/time

 Measuring Times

 Over 5000 times (Short-circuit test, interval time should be at least 30seconds)

 Short-circuit Test Current

 AC 20mA max

 Open-circuit Test Voltage

 AC 40V max

 Test Voltage Wave

 Sine wave

 Electrode Distance Range

1m-100m

 Line Voltage

 Measurement below AC 600V

 Data Hold

 Data hold function: “HOLD” symbol display

 Data Access

 Data read function: “READ” symbol display

 Overflow Display

 Exceed measuring range overflow function: “OL” symbol display

 Auxiliary Grounding Test

 With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)

 Interference Test

 Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V

 Alarm Function

 Measuring value exceeds alarm setting value, will "Toot-toot-toot" alarm hint

 Battery Voltage

 While battery voltage decreases to around 7.5V, will display battery voltage low symbol“     ”, and reminding to replace the battery

 Overload Protection

 Measure earth resistance: between each interfaces of E-P、E-E- C,AC 280V/3 seconds

 Insulation Resistance

 Over 20MΩ(between circuit and outside shell is 500V)

 Withstand Voltage

 AC 3700V/rms. (Between circuit and outside shell)

 Electromagnetic Features

 IEC61010- 4-3,Wireless frequency electromagnetic field ≤1 V/m

 Protection Type 

 IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、Pollution 2);

 IEC61010-031;

 IEC61557-1(Earth resistance);

 IEC61557-5(Soil resistivity); 

 JJG 366-2004(Grounding resistance meter)

 Weight

1653g

 Meter Dimension

 215mm(L)×190mm(W)×95mm(H)


Note:Batteries are not included during the shipping !!!

Relate Model:

Package Outer package Carton
 Inner package Aluminum case
 Accessory Meter1 PCS
 Current clamp  2 PCS
 Aluminum case1 PCS
 Auxiliary grounding rod(10x150mm)4 PCS
 Test cable yellow 10 meters1 PCS
 Test cable green 10 meters1 PCS
 Test cable red 20 meters1 PCS
 Test cable black 20 meters1 PCS
 Test cable black1.6 meters1 PCS
 Test cable red 1.6 meters1 PCS
 RS232 communication cable1 PCS
 CD1 PCS
 Manual1 PCS
 Certificate1 PCS