1. Indicators
Gen frequency
Over/under speed
Gen voltage
Low oil pressure
Battery voltage
High water temperature
Accumulated time
Charging abnormal
Emergency stop
Over voltage
2. Buttons introduction
Display buttons:
Operation:
1. Power on : Switch “0”to “I” till the tube is lighted, In the procession of cranking, over speed indicator will be lighted if the crank is not successful after 45sec.(controller will cut off fuel solenoid’s output and come into protection)
2. Start running: Switch “I ” to “II” till engine started. Once power on the engine, it will be cranked. the controller will come into running status after 8 sec if cranking successfully. Then the controller will monitor the relative parameters and set protection.(the controller will cut off fuel solenoid output and display the alarm status if the genset is stopped.)Please Switch from “I”to “0”.
3. Stop and reset:Switch from “I”to “0” and take off the power.
Parameter setting:
Please connect the module to PC by communication cables and powered on.
1. Alarm setting
Over speed alarm: 1710RPM(Rated 50Hz), 2040RPM(Rated 60Hz), range: 0-4000RPM, when the RPM is over this value and keep more than 1sec, then the controller will alarm and stop.
Over frequency alarm: 57Hz(Rated 50Hz), 68Hz(Rated 60Hz),range:40-80Hz, when the frequency is over this value and keep more than 1 sec, then the controller will alarm and stop.
Low frequency alarm: 20Hz, range: 20-60Hz,when the frequency is lower than the value and keep more than 5sec, the controller will alarm and stop.
Over voltage alarm: 500V, range:50-500v, 500V is set as forbidden. When the voltage is over this value and keep more than 5sec,then the controller will alarm and stop.
Charging failure D- value:6V,range:1-24V, when the different value between charging D+ and Battery B+ is over this value and keep more than 5sec, then the controller will alarm.
Four Screen self-cycling display: the parameters shall be switched timely according to the interval time setting after choosing this option.
Homepage option: one parameter can be displayed as homepage display after choosing this function. The page will be switched automatically after pressing page change button for a while.
Revert-back delay: the time to revert back to homepage.
Self-cycling display time: the interval time setting.
Technical Specifications:
Power supply:8-33VDC
Power consumption:MAX 2W(Working
Alternator Voltage input:15-300VAC,50/60H
Speed input:Freq 300Hz~10kH
Fuel output:MAX 16
Start output:MAX 10
Excitation Output:MAX 80m
Alarm output:MAX 16
Operating temperature:-30-75
Storage temperature:-40-85
Dimensions:78×78×72m
Pannel cutout:67×67m
Weight:280g