1

Power Quality Analyzer 3 Phase Power Quality Analyzer with Current 10A ~ 6000A


This Power Quality Analyzer comes with 4PCS DZF-3Q-6000A Flexible Coil Current Sensors, 10A ~ 6000A Range , Ф300mm

If you needs other sensors, please contact us.

Introduction:

Specification:

Power supply

Rechargeable lithium-ion battery packs 9.6V, backup charger.

Battery Level indicator

Battery symbol 5 grid   Display power, when the battery level is low, automatically shut down after 1 minute indication

Working Current

about 590mA, continuous working 8hours.

Display mode

LCD color screen, 640dots × 480dots, 5.6 inches, display field 116mm × 88mm

Instrument Size

240mm×170mm×68 mm.

CT Size

DZF-3Q-6000A Flexible Coil Current Sensor (with Integrator) : Ф300mm

Number of channels

4 voltages, 4 currents

Line Voltage

1.0V~2000V.

Phase Voltage

1.0V~1000V.

Current

DZF-3Q-6000A Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A

Frequency

40Hz~70Hz.

Electricity Energy Parameter

W, VA, Var, PF, DPF, cosφ, tanφ.

Energy parameters

Wh, Varh, Vah.

Harmonic Wave

Yes, 0-50 times

Total harmonic distortion

Yes, 0 - 50 times, each phase

Expert Mode

Yes.

Transient Record Groups

150 groups

Voltage Flicker

Yes

Start Current Mode

Yes, 100 seconds

Three-phases Unbalance

Yes

Record

300 days (record 20 parameters simultaneously, every 5 seconds record 1 point)

Min/Max Recorded Value

Yes, the max min value can be measured for a certain time

Alarm

40 different types of parameter selection, 12800 group alarm logs

Peak

Yes.

Phasor Diagram Display

Automatic

Screenshot Capacity

60PCS

Menu language

English/Chinese.

Communication Interface

USB.

Automatic Shut Down

In the alarm/trend graph recording/transient capture mode (waiting or in progress), the instrument does not automatically shut down

In other test modes, there is no button operation within 15 minutes, prompting to automatically shut down after 1 minute.

Backlight Function

Yes, suitable for dark places and nighttime use

Instrument Weight

Host: 1.6kg (with battery).

DZF-3Q-6000A Flexible Coil Current Sensor (with Integrator) : 330g×4;

Test wires and power adapter: 900g;

Total weight: about 9.2kg (with package).

Voltage Test Wire Length

3M

Current Clamp Wire Length

2M

Working Temperature

-10°C~40°C; below 80%Rh.

Storage Temperature

-10°C~60°C; below 70%Rh.

Input Impedance

Test voltage input impedance: 1MΩ

Withstand voltage

Withstand the sine wave AC voltage of 3700V/50Hz one minute between the instrument line and out shell

Insulation

Between instrument line and shell ≥10MΩ.

Structure

Double insulation, with insulation shock-proof sheath.

Suitable Safely Standard

IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.

Accessories

Host: 1PCS; Instrument Bag: 1pcs; Test Cable: 5PCS (yellow, green, red, blue, black);

Alligator Clip: 5PCS; Probe: 5PCS; Charger 1PCS; 

Software CD: 1COPY; 2G Memory Card: 1PCS. DZF-3A-6000A Flexible Coil Current Clamp 4PCS