Power Quality Analyzer 3 Phase Power Quality Analyzer with Current 10A ~ 6000A
This Power Quality Analyzer comes with 4PCS DZF-3Q-6000A Flexible Coil Current Sensors, 10A ~ 6000A Range , Ф300mm
If you needs other sensors, please contact us.
Introduction:
Specification:
Power supply | Rechargeable lithium-ion battery packs 9.6V, backup charger. |
Battery Level indicator | Battery symbol 5 grid Display power, when the battery level is low, automatically shut down after 1 minute indication |
Working Current | about 590mA, continuous working 8hours. |
Display mode | LCD color screen, 640dots × 480dots, 5.6 inches, display field 116mm × 88mm |
Instrument Size | 240mm×170mm×68 mm. |
CT Size | DZF-3Q-6000A Flexible Coil Current Sensor (with Integrator) : Ф300mm |
Number of channels | 4 voltages, 4 currents |
Line Voltage | 1.0V~2000V. |
Phase Voltage | 1.0V~1000V. |
Current | DZF-3Q-6000A Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A |
Frequency | 40Hz~70Hz. |
Electricity Energy Parameter | W, VA, Var, PF, DPF, cosφ, tanφ. |
Energy parameters | Wh, Varh, Vah. |
Harmonic Wave | Yes, 0-50 times |
Total harmonic distortion | Yes, 0 - 50 times, each phase |
Expert Mode | Yes. |
Transient Record Groups | 150 groups |
Voltage Flicker | Yes |
Start Current Mode | Yes, 100 seconds |
Three-phases Unbalance | Yes |
Record | 300 days (record 20 parameters simultaneously, every 5 seconds record 1 point) |
Min/Max Recorded Value | Yes, the max min value can be measured for a certain time |
Alarm | 40 different types of parameter selection, 12800 group alarm logs |
Peak | Yes. |
Phasor Diagram Display | Automatic |
Screenshot Capacity | 60PCS |
Menu language | English/Chinese. |
Communication Interface | USB. |
Automatic Shut Down | In the alarm/trend graph recording/transient capture mode (waiting or in progress), the instrument does not automatically shut down |
In other test modes, there is no button operation within 15 minutes, prompting to automatically shut down after 1 minute. | |
Backlight Function | Yes, suitable for dark places and nighttime use |
Instrument Weight | Host: 1.6kg (with battery). |
DZF-3Q-6000A Flexible Coil Current Sensor (with Integrator) : 330g×4; | |
Test wires and power adapter: 900g; | |
Total weight: about 9.2kg (with package). | |
Voltage Test Wire Length | 3M |
Current Clamp Wire Length | 2M |
Working Temperature | -10°C~40°C; below 80%Rh. |
Storage Temperature | -10°C~60°C; below 70%Rh. |
Input Impedance | Test voltage input impedance: 1MΩ |
Withstand voltage | Withstand the sine wave AC voltage of 3700V/50Hz one minute between the instrument line and out shell |
Insulation | Between instrument line and shell ≥10MΩ. |
Structure | Double insulation, with insulation shock-proof sheath. |
Suitable Safely Standard | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |
Accessories | Host: 1PCS; Instrument Bag: 1pcs; Test Cable: 5PCS (yellow, green, red, blue, black); Alligator Clip: 5PCS; Probe: 5PCS; Charger 1PCS; Software CD: 1COPY; 2G Memory Card: 1PCS. DZF-3A-6000A Flexible Coil Current Clamp 4PCS |